Page 56 / 202 Scroll up to view Page 51 - 55
5 - Information / Configuration
Page 5-20
SAGEM F@st™ 1704 Reference Manual - 253272861-A
Sagem Communications SAS
document. Reproduction and disclosure prohibited
Field
Action
Default
value
Peak Cell Rate
2
Enter a maximum number of cells transmitted
per second, between 1 and 2491.
-
Sustainable Cell Rate
3
Enter an average number of cells transmitted
per second.
Note:
This number must be lower than the
P
eak
C
ell
R
ate (PCR).
-
Maximum Burst Size
3
Enter the maximum number of cells emitted in
burst (value between 1 and 1000 000).
-
Encapsulation modes
DSL Link type
Action
Default value
EoA
(Ethernet over ATM)
Select the encapsulation of your choice from the
scroll down list.
LLC/SNAP-BRIDGING,
VC/MUX.
LLC/SNAP-
BRIDGING
PPPoA
(PPP over ATM)
Select the encapsulation of your choice from the
scroll down list.
VC/MUX,
LLC/ENCAPSULATION.
VC/MUX
IPoA
(IP over ATM)
Select the encapsulation of your choice from the
scroll down list.
LLC/SNAP-ROUTING,
VC/MUX.
LLC/SNAP-
ROUTING
Select Connection Mode
The Connection Mode selection only appears if you have selected the EoA DSL link type.
Field
Action
Default
value
Default mode
Check this box to configure a single service
over one connection.
Checked
VLAN MUX Mode
Check this box to configure Multiple Vlan
service over one connection.
Not
checked
MSC Mode
Check this box to configure Multiple Service
over one connection.
Not
checked
Enable Quality Of Service
Field
Action
Default
value
Enable Quality Of Service
Check the box to activate the quality of
service.
Not checked
2
This field only appears when the "UBR with PCR", "CBR", "Non Realtime VBR" or "Realtime VBR" type of
service is selected.
3
These fields only appear when the "Non Realtime VBR" or "Realtime VBR" type of service is selected.
Page 57 / 202
5 - Information / Configuration
SAGEM F@st™ 1704 Reference Manual - 253272861-A
Page 5-21
Sagem Communications SAS
document. Reproduction and disclosure prohibited
5.7.2
WAN Service
Object:
This menu is associated with the remote network. It is used to display the list of all the
configured PVCs, and to add PVCs or remove them.
In the
Advanced Setup
menu, select
WAN Service
.
The following screen opens:
Field
Meaning
Interface
Name, allocated automatically, associated with the service name (for example,
ATM interface "ppp_0_35_1" associated with the ATM service
pppoe_0_35_1).
Description
Name of the ATM service. This name is made up as follows:
Protocol_VPI_VCI_Index
For example: pppoe_0_35_1.
Type
Data flow encapsulation mode.
Vlan8021p
4
Value of the 802.1P Priority.
VlanMuxId
4
Value of the 802.1Q VLAN ID.
ConnID
Connection Identification. This is used to identify the different PPP
connections which belong to the same PVC. To do so, you need only
increment the "VC number" in the "Service" field when adding a new "PVC".
IGMP
Status (Enabled or Disabled) of the IGMP function. (see Note).
NAT
Status (Enabled or Disabled) of the NAT.
Firewall
Status (Enabled or Disabled) of the Firewall.
IPv6
Status (Enabled or Disabled) of the IPv6.
MLD
Status (Enabled or Disabled) of the MLD.
Note
This function enables the distribution of Multicast datagrams over the local
network (LAN) and interaction between the router and the local network hosts.
4
These values only appear if the WAN service is configured over a DSL ATM interface using VLAN MUX Mode.
Page 58 / 202
5 - Information / Configuration
Page 5-22
SAGEM F@st™ 1704 Reference Manual - 253272861-A
Sagem Communications SAS
document. Reproduction and disclosure prohibited
5.7.2.1
Add
Note
You must have configured a DSL ATM interface (see section 5.7.1) to add a
WAN service.
Click on the
Add
button.
Select the DSL ATM interface for the WAN service.
Click on the
Next
button to continue configuring the WAN service.
Note
Depending on the type of network protocol configured for the selected DSL
ATM interface (EoA, PPPoA or IPoA), the content of the following WAN
interface configuration screens differs.
Therefore, and for more clarity, each type of protocol will be dealt with
separately (screens + associated summary tables) below.
Page 59 / 202
5 - Information / Configuration
SAGEM F@st™ 1704 Reference Manual - 253272861-A
Page 5-23
Sagem Communications SAS
document. Reproduction and disclosure prohibited
5.7.2.2
Ethernet over ATM – PPP over Ethernet (PPPoE)
Select the WAN service type
PPP over Ethernet (PPPoE)
.
Field
Action
Default value
Enter Service description
Displays the name of the service being
configured. This name, which is allocated
automatically, is made up as follows:
Protocol_VPI_ Index _ VCI
For example: pppoe_0_0_35.
Note:
You may enter another service name.
pppoe_0_0_35
Enter 802.1P Priority
5
Enter a value for the 802.1P Priority. This value
is between 0 and 7.
-1
Enter 802.1Q VLAN ID
5
Enter a value for the 802.1QVLAN ID. This
value is between 0 and 4094.
-1
Enable IPv6 for this
service
Check this box to enable IPv6 for this service.
Not checked
Click on the
Next
button to continue configuring the WAN service.
5
These values only appear if the WAN service is configured over a DSL ATM interface using VLAN MUX Mode.
Page 60 / 202
5 - Information / Configuration
Page 5-24
SAGEM F@st™ 1704 Reference Manual - 253272861-A
Sagem Communications SAS
document. Reproduction and disclosure prohibited
Field
Action
Default value
PPP Username
Enter your connection ID.
This information is provided to you by your
I
nternet
S
ervice
P
rovider (ISP).
-
PPP Password
Enter your connection password.
This information is provided to you by your
I
nternet
S
ervice
P
rovider (ISP).
-
PPPoE Service
Name
Enter the name of the PPPoE service.
This information is provided to you by your
I
nternet
S
ervice
P
rovider (ISP).
-
Authentication
Method
Select the authentication method of your choice from the
scroll down list:
AUTO,
PAP,
CHAP,
MSCHAP.
AUTO
Dial on demand
(with idle timeout
timer)
Check the box to only connect to the Internet on "Traffic".
Not checked
Inactivity Timeout
(minutes) [1-4320]:
6
Enter the inactivity time. This value (in minutes) is
between 1 and 4320
(i.e. 72 hours).
If there is no traffic for a certain period of time, the PPPoE
session is interrupted.
0
6
This field only appears when the "Dial on demand (with idle timeout timer)" field is activated (box checked).

Rate

4 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top