Page 61 / 88 Scroll up to view Page 56 - 60
´1
D-Link DCS-3110 User Manual
Section ² - Configuration
DI and DO:
Digital input
trigger condition:
Digital output:
Settings for both Digital input signal and digital
output signal can be configured here.
Please select
High
or
Low
for digital input trigger
condition. When an external device is connected
to the digital input pins, the state of the voltage
will be monitored. (Max. Input 500mA, 12Vdc)
Select
Grounded
or
Open
to define normal status
of the digital output. The camera will show whether
the trigger is activated or not.
Advanced
DI and DO
The I/O connector provides the physical interface for digital output (DO) and digital input (DI) that is used for connecting
such external alarm devices as IR-Sensors and alarm relays to the network camera.
Page 62 / 88
´±
D-Link DCS-3110 User Manual
Section ² - Configuration
With digital PTZ (Pan/Tilt/Zoom) feature enabled, it is possible to zoom
in and out video recieved from the DCS-3110.
Enable PTZ Operation
To utilize this feature, please connect the DCS-3110 to a PTZ scanner via
RS485 interface and follow the instructions given below. Three PTZ drivers are
supported:
• DynaDome/SmartDOME
• Lilin PIH-7x00
• Pelco D protocol
Note:
If none of the above PTZ drivers is supported by your PTZ scanner, please
select
Custom camera
.
1. Connect to your PTZ scanner, set the Camera ID, PTZ driver, and Port
settings.
2. Select
Enable PTZ Operation
and then click
Save
to take effect.
3. The PTZ control buttons will be displayed in the main page.
Preset Position
Click
Preset Position
to set the preset position for the Network Camera. A total of
20 preset positions can be configured.
To set a preset position, follow the steps given below:
1. Adjust the Network Camera to a desired position using the buttons on the
right side of the window.
2. In the
Preset position name
text box, enter a descriptive name for the preset
position. You can enter up to 40 characters in the text box.
3. Click
Add
. The preset position name will appear in the drop-down list.
To remove a preset position from the list, select a preset position name from the
drop-down list and then click
Delete
.
RS485
Page 63 / 88
´3
D-Link DCS-3110 User Manual
Section ² - Configuration
Custom Command
Click
Custom Command
to open the Custom Command page. In this page, you
can set addition command buttons for controlling the PTZ scanner. A total of five
command buttons can be configured.
To add a new control button, follow the steps below.
1. In the
Button name
text box, enter the descriptive name for the control
button.
2. Refer to the PTZ scanner and enter the command.
3. Click
Save
to take effect and click
Close
to quit this page.
4. The new custom command button will be displayed in the main page.
NOTE :
If Custom camera is selected as the PTZ driver, the PTZ control buttons will not
take effect. Please go to
Configuration > Camera control >
Custom Command
to set the commands in the Control settings session. Please refer to the user manual of the PTZ scanner for the command.
Page 64 / 88
´²
D-Link DCS-3110 User Manual
Section ² - Configuration
ICR
- IR-Cut Removable(ICR) filter is a switch mechanical design
of two different sensor filters. It provides the best light conditions
both during the day and night. The following options are:
ICR
Auto:
Day Mode:
Night Mode:
Schedule Mode:
The Network Camera automatically switches
between day and night mode by judging the level
of ambient light. This mode is accessible only
when the exposure mode is set to
Auto
.
In this mode the Network Camera switches on
the infrared cut filter at all times, which will block
the infrared light from reaching the sensor so that
the colors are not distorted.
The Network Camera switches off the infrared cut
filter to allow the infrared light to pass through.
This helps the Network Camera to see more
clearly in low light conditions.
The Network Camera switches between day and
night mode based on a specific schedule.
Ensure to enter the starting and ending time for
the day mode. Note that the time format is [hh:
mm] and is expressed in 24-hour clock time. By
default, the starting time and ending time of day
mode are set to 07:00 and 18:00.
Page 65 / 88
´³
D-Link DCS-3110 User Manual
Section ² - Configuration
Allow list:
Start IP address:
End IP address:
Delete allow list:
Deny list:
Delete deny list:
The list of IP addresses that have the access right
to the camera.
The starting IP Address of the devices (such
as a computer) that have permission to access
the video of the camera. Click
Add
to save the
changes made.
Note:
A total of ten lists can be configured for
both columns.
The ending IP Address of the devices (such as
a computer) that have permission to access the
video of the camera.
Remove the customized setting from the Allow
List.
The list of IP addresses that have no access right
to the camera.
Remove the customized setting from the Delete
List.
Access List
The Access List page will allow you to configure access permissions for each user.
For example:
When the range of allowed list is set from 1.1.1.0 to 192.255.255.255
and the range of denied list is set from 1.1.1.0 to 170.255.255.255, Only
users’ IP located between 171.0.0.0 and 192.255.255.255 can access
the Network Camera.
Alowed
List
Denied
List

Rate

3.5 / 5 based on 2 votes.