Rear Panel
The rear of the Data Gateway has the following connectors and controls:
A
Ethernet (1 - 4)
: connectors for use with a computer LAN port.
B
USB:
USB host connector - future support for external USB devices
C
Reset
button: resets the Data Gateway as if you power cycled the unit. Use
a pointed non-metallic object to press this button.
D
Cable
: connector for the coaxial cable.
E
Power
: connector for the power cord.
F
Power Switch
: (DG950S only): power On/Off switch.
Touchstone DG950 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
16
DG950A
DG950S
Ethernet
10/100/1000
USB
Reset
Cable
1
2
3
4
C
A
B
E
Ethernet
10/100/1000
USB
Reset
Cable
1
2
3
4
D
C
A
B
E
D
F
Page 17 / 49
17
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
Touchstone DG950 Data Gateway User’s Guide
Selecting an Installation Location
There are a number of factors to consider when choosing a location to install your
Data Gateway:
Is an AC outlet available nearby? For best results, the outlet should not be
switched and should be close enough to the Data Gateway that extension
cords are not required.
Is a cable jack available? For best performance, keep the number of split-
ters between the jack and cable drop to a minimum. Each splitter attenuates
(reduces) the signal available to the Data Gateway. A large number of split-
ters can slow down the Internet connection.
If you are connecting devices to the Ethernet ports, can you easily run ca-
bles between the Data Gateway’s location and those devices?
If you want to mount the Data Gateway on a wall, does the location provide
a solid surface for secure attachment? For best results when mounting the
Data Gateway on drywall, position the Data Gateway so at least one of the
screws are fastened to a stud. This may prevent the Data Gateway from
pulling out of the wall in the future.
If you want to install the Data Gateway on a desktop, is there enough space
on either side to keep the vents clear? Blocking the vents may cause over-
heating.
How close are your wireless devices? The Data Gateway wireless connection
range is typically 100–200 feet (30m–65m). A number of factors can affect
connection range, as described below.
Page 18 / 49
Factors Affecting Wireless Range
A number of factors can affect the usable range for wireless connections.
Note:
Note that decreasing the range of your wireless network may be bene-
ficial, as long as the decreased range is sufficient for your needs. By lim-
iting your network’s range, you reduce interference with other networks
and make it harder for unwanted users to find and connect to your net-
work.
Increases range:
Raising the unit above the devices (for example, in-
stalling the Data Gateway in the upper floor of a multi-
story dwelling)
Adding wireless hubs in a bridge (WDS) network
Setting the trasmit power level to High
Decreases range:
Lowering the unit below the devices (for example, in-
stalling the Data Gateway in a basement)
Metal or concrete walls between the Data Gateway and
other devices
Large metal appliances, aquariums, or metal cabinets
between the Data Gateway and other devices
Interference and RF noise (2.4 GHz wireless phones,
microwave ovens, or other wireless networks)
Setting the trasmit power level to Medium or Low
Touchstone DG950 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
18
Page 19 / 49
Mounting the Data Gateway
You can either mount the Data Gateway on a wall or place it on a desktop. For
wall-mount applications, you can mount the Data Gateway with the indicators
facing upward (vertical) or to the side (horizontal).
Tools and Materials
For wall-mounted installations, make sure you have the following tools and mate-
rials before proceeding:
for mounting on drywall: Two 1/4” (6mm) drywall anchors and a drill with
1/4” (6mm) bit (not included)
for mounting on plywood or studs: two #6 x 1.5” (38.1 mm) self tapping
screws (not included)
screwdriver (flat-blade or Phillips, depending on what kind of screws you
use)
wall-mount template (included)
transparent tape: for temporarily securing the mounting template to the wall
(not included)
Location
Always position the Data Gateway:
within reach of an AC outlet. The power cord must reach the outlet without
stretching and without adding extension cords.
near a cable outlet (to avoid long cable runs).
Touchstone DG950 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
19
Step 1
Step 2
Step 3
Step 4
Page 20 / 49
20
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
Touchstone DG950 Data Gateway User’s Guide
Instructions
Wall-mounting instructions
Note
:
When mounting the Data Gateway on drywall, try to position the Data
Gateway so at least one of the screws is fastened to a stud. This may
prevent the Data Gateway from pulling out of the wall in the future. To
prevent overheating of the Data Gateway, do not block the ventilation
holes on the sides of the unit.
1
Position the mounting template on the surface where you intend to mount
the Data Gateway and secure in place with transparent tape.
2
Drill holes through the template in the specified locations for the mounting
screws. After drilling holes, remove the template from the surface.
3
If using drywall anchors, set them into the wall. Then, drive the screws into
the wall leaving a gap of about 1/8” (3 mm) between the screw head and
the wall. If not using anchors, just drive the screws.
4
Orient the Data Gateway with the indicator lights facing up or right, as de-
sired. Slip both mounting slots (in the back of the Data Gateway) over the
screws, then slide the case down until the narrow end of the keyhole slot
contacts the screw shaft.
5
Proceed to
Connecting the Data Gateway
.
Desktop mounting instructions
1
Position the Data Gateway so that:
air flows freely around it
the back faces the nearest wall
it will not fall to the floor if bumped or moved
the ventilation holes on the side of the unit are not blocked.
2
Proceed to
Connecting the Data Gateway
.