Chapter 2 - CPE Installation
BreezeMAX Si 4000 Hardware Description
BreezeMAX Si 4000 CPE
22
Operator Manual
2.3.3
Reset Button
The recessed button is used to reset the BreezeMAX Si 4000 or to restore the unit
to factory default configuration.
Do not perform reset to factory default unless specifically instructed by
customer support.
To perform a hardware reset, press the button for approximately 1 second.
To restore the device to the factory default settings, press and hold the button
for 5 seconds or more; any configuration changes you made are removed and
the factory default configuration is restored to the unit.
Some user-configured parameters will be lost and must be reconfigured.
2.3.4
WiMAX Antennas
Two built-in omnidirectional antennas are included with the BreezeMAX Si 4000
for WiMAX communications. The omnidirectional antennas transmit and receive
signals in all directions equally.
2.3.5
BreezeMAX Si 4000Cables
Use only Category 5E Ethernet cables from either Alvarion or any of the approved
manufacturers, listed in
Table 2-4
. Consult with Alvarion's specialists on the
suitability of other cables.
NOTE
The length of the Ethernet cable connecting the BreezeMAX Si 4000 to the data equipment, must
not exceed 100 meters.
Table 2-4: Approved Category 5E Ethernet Cables
Manufacturer
Part Number
Superior Cables Ltd.
www.superior-cables.com
612098
HES Cabling Systems
www.hescs.com
H5E-00481
Teldor
www.teldor.com
8393204101