Ont SN
: 6877687714852901
Password
:
VenderID
: HWTC
Ont Version
: 120D0010
Ont SoftwareVersion : V1R003C00
Ont EquipmentID
: 247
Ont autofind time
: 2011-02-10 14:59:12
---------------------------------------------------------------------
---
huawei(config-if-gpon-0/1)#
ont confirm 1 ontid 1 sn-auth
6877687714852900 omci ont-lineprofile-id 10 ont-srvprofile-id 10
huawei(config-if-gpon-0/1)#
ont confirm 1 ontid 2 sn-auth
6877687714852901 omci ont-lineprofile-id 10 ont-srvprofile-id 10
NOTE
If multiple ONTs of the same type are connected to a port and the same line profile or service
profile is bound to the ONTs, you can add ONTs in batches by confirming the auto discovered
ONTs in batches to simplify the operation and increase the configuration efficiency. For
example, the preceding command can be modified as follows:
huawei(config-if-gpon-0/1)#
ont confirm 1 all sn-auth omci ont-
lineprofile-id 10 ont-srvprofile-id 10
(3)
(Optional) Bind an alarm profile to the ONT.
In this example, bind the default alarm profile, namely alarm profile 1 to the
ONT.
huawei(config-if-gpon-0/1)#
ont alarm-profile 1 1 profile-id 1
huawei(config-if-gpon-0/1)#
ont alarm-profile 1 2 profile-id 1
5.
Confirm that the ONT goes online normally.
After an ONT is added, run the
display ont info
command to query the current status
of the ONT. Ensure that
Control flag
of the ONT is
active
,
Run State
is
online
,
Config state
is
normal
, and
Match state
is
match
.
huawei(config-if-gpon-0/1)#
display ont info 1 1
---------------------------------------------------------------------
F/S/P
:
0/1/1
ONT-ID
:
1
Control flag
:
active
//Indicates that the ONT is
activated.
Run state
:
online
//Indicates that the ONT goes online
normally.
Config state
:
normal
//Indicates that the configuration status
of the
ONT is normal.
Match state
:
match
//Indicates that the capability profile
bound to
the ONT is consistent with the
actual capability
of the ONT.
...//The rest of the response information is omitted.
If the ONT state fails, the ONT fails to be in the up state, or the ONT does not match,
check the ONT state by referring to the above-mentioned descriptions.
–
If
Control flag
is
deactive
, run the
ont activate
command in the GPON port mode
to activate the ONT.
–
If the ONT fails to be in the up state, that is,
Run state
is
offline
, the physical line
may be broken or the optical transceiver may be damaged. You need to check both
the material and the line.
EchoLife HG8010/HG8240B/HG8245T/HG8247T GPON
Terminal
Service Manual
3 Configuration
Issue 01 (2011-10-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.