Page 6 / 29 Scroll up to view Page 1 - 5
1
Safety Precautions
Thank you for purchasing the EchoLife HG532 Home Gateway (hereinafter referred to
as the HG532).
To use the device properly and safely, read these warnings and precautions carefully
and strictly observe them during operation. Unless otherwise specified, the term
"device" refers to the device and its accessories.
Basic Requirements
z
During storage, transportation, and operation of the device, keep it dry and prevent
it from colliding with other objects.
z
Do not dismantle the device. In case of any fault, contact an authorized service
center for assistance or repair.
z
Without authorization, no organization or individual can change the mechanical,
safety, or performance design of the device.
z
When using the device, observe all applicable laws and regulations and respect the
legal rights of other people.
Environmental Requirements for Using the Device
z
Before connecting and disconnecting cables, stop using the device, and then
disconnect it from the power supply. Ensure that your hands are dry during
operation.
z
Keep the device far from sources of heat and fire, such as a heater or a candle.
z
Keep the device far from electronic appliances that generate strong magnetic or
electric fields, such as a microwave oven or a refrigerator.
z
Place the device on a stable surface.
z
Place the device in a cool and well-ventilated indoor area. Do not expose the device
to direct sunlight.
z
Use the device in an area with a temperature ranging from 0°C to 40°C.
z
Do not block the openings on the device with any object. Reserve a minimum space
of 10 cm around the device for heat dissipation.
z
Do not place any object (such as a candle or a water container) on the device. If any
foreign object or liquid enters the device, stop using the device immediately, power
it off, remove all the cables connected to it, and then contact an authorized service
center.
1
Page 7 / 29
z
During thunderstorms, power off the device, and then remove all the cables
connected to it to prevent it from getting damaged due to lightning strikes.
Precautions for Using Wireless Devices
z
When using the device, ensure that the antenna of the device is at least 20 cm away
from all persons.
z
Do not use the device where using wireless devices is prohibited or may cause
interference or danger.
z
The radio waves generated by the device may interfere with the operation of
electronic medical devices. If you are using any electrical medical device, contact
its manufacturer for the restrictions on the use of the device.
z
Do not take the device into operating rooms, intensive care units (ICUs), or
coronary care units (CCUs).
Areas with Inflammables and Explosives
z
Do not use the device where inflammables or explosives are stored, for example, in
a gas station, oil depot, or chemical plant. Otherwise, explosions or fires may occur.
In addition, follow the instructions indicated in text or symbols.
z
Do not store or transport the device in the same box as inflammable liquids, gases,
or explosives.
Accessory Requirements
z
Use only the accessories supplied or authorized by the device manufacturer.
Otherwise, the performance of the device may get affected, the warranty for the
device or the laws and regulations related to telecommunications terminals may
become null and void, or an injury may occur.
z
Do not use the power adapter if its cable is damaged. Otherwise, electric shocks or
fires may occur.
z
Ensure that the power adapter meets the specifications indicated on the device
nameplate.
z
Ensure that the power adapter meets the requirements of Clause 2.5 in
IEC60950-1/EN60950-1 and it is tested and approved according to national or local
standards.
Safety of Children
Keep the device and its accessories out of the reach of children. Otherwise, they
may damage the device and its accessories by mistake, or they may swallow the
small components of the device, causing suffocation or other dangerous situations.
2
Page 8 / 29
Maintenance
z
If the device is not used for a long time, power it off, and then remove all the cables
connected to it.
z
If any exception occurs, for example, if the device emits any smoke or unusual
sound or smell, stop using the device immediately, power it off, remove all the
cables connected to it, and then contact an authorized service center.
z
Do not trample, pull, or overbend any cable. Otherwise, the cable may get damaged,
causing malfunction of the device.
z
Before cleaning the device, stop using it, power it off, and then remove all the
cables connected to it.
z
Use a clean, soft, and dry cloth to clean the device shell. Do not use any cleaning
agent or spray to clean the device shell.
3
Page 9 / 29
2
Connecting the Cables and Getting
Started
2.1
Simple Connection
If your telephone line is used for the broadband network access only and do not need to
use a telephone, take the following figure as a reference for connecting the cables.
1
2
3
POWER
LAN4
LAN3
LAN2
LAN1
USB
RESET
ADSL
1. Telephone jack on the wall
2. Power adapter
3. Computer
If the wireless network function is used on the HG532 for the network
access, you do not need to connect the cables.
4
Page 10 / 29
2.2
Connecting One Telephone
If your telephone line is used for both the broadband network access and a telephone
connection, take the following figure as a reference for connecting the cables.
#
#
#
1
3
4
5
PHONE
LINE
MODEM
2
POWER
LAN4
LAN3
LAN2
LAN1
USB
RESET
ADSL
1. Telephone jack on the wall
2. Splitter
3. Power adapter
4. Computer
5. Telephone
2.3
Connecting Multiple Telephones
If your telephone line is used for the broadband network access, telephone connections,
and fax connections, take the following figure as a reference for connecting the cables.
5

Rate

4 / 5 based on 1 vote.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top