Overview
This chapter explains how to configure the Device’s TR-064 auto-configuration settings.
29.2
The TR-064 Screen
TR-064 is a LAN-Side DSL CPE Configuration protocol defined by the DSL Forum. TR-064 is built on
top of UPnP. It allows the users to use a TR-064 compliant CPE management application on their
computers from the LAN to discover the CPE and configure user-specific parameters, such as the
username and password.
Click
Maintenance > TR-064
to open the following screen.
Figure 132
Maintenance > TR-064
The following table describes the fields in this screen.
Table 104
Maintenance > TR-064
LABEL
DESCRIPTION
State
Select
Enable
to activate management via TR-064 on the LAN.
Apply
Click
Apply
to save your changes.
Cancel
Click
Cancel
to exit this screen without saving.
Page 262 / 367
Chapter 29 TR-064
VMG4380-B10A / VMG4325-B10A User’s Guide
262
Page 263 / 367
VMG4380-B10A / VMG4325-B10A User’s Guide
263
C
HAPTER
30
Time Settings
30.1
Overview
This chapter shows you how to configure system related settings, such as system time, password,
name, the domain name and the inactivity timeout interval.
30.2
The Time Screen
To change your Device’s time and date, click
Maintenance > Time
. The screen appears as shown.
Use this screen to configure the Device’s time based on your local time zone.
Figure 133
Maintenance > Time Setting
Page 264 / 367
Chapter 30 Time Settings
VMG4380-B10A / VMG4325-B10A User’s Guide
264
The following table describes the fields in this screen.
Table 105
Maintenance > Time Setting
LABEL
DESCRIPTION
Current Date/Time
Current Time
This field displays the time of your Device.
Each time you reload this page, the Device synchronizes the time with the time server.
Current Date
This field displays the date of your Device.
Each time you reload this page, the Device synchronizes the date with the time server.
NTP Time Server
First ~ Fifth NTP
time server
Select an NTP time server from the drop-down list box.
Otherwise, select
Other
and enter the IP address or URL (up to 29 extended ASCII
characters in length) of your time server.
Select
None
if you don’t want to configure the time server.
Check with your ISP/network administrator if you are unsure of this information.
Time Zone
Time zone offset
Choose the time zone of your location. This will set the time difference between your time
zone and Greenwich Mean Time (GMT).
Daylight Saving
Daylight Saving Time is a period from late spring to early fall when many countries set
their clocks ahead of normal local time by one hour to give more daytime light in the
evening.
State
Select
Enable
if you use Daylight Saving Time.
Start rule:
Configure the day and time when Daylight Saving Time starts if you enabled Daylight
Saving. You can select a specific date in a particular month or a specific day of a specific
week in a particular month. The
Time
field uses the 24 hour format. Here are a couple of
examples:
Daylight Saving Time starts in most parts of the United States on the second Sunday of
March. Each time zone in the United States starts using Daylight Saving Time at 2 A.M.
local time. So in the United States, set the day to
Second
,
Sunday
, the month to
March
and the time to
2
in the
Hour
field.
Daylight Saving Time starts in the European Union on the last Sunday of March. All of the
time zones in the European Union start using Daylight Saving Time at the same moment
(1 A.M. GMT or UTC). So in the European Union you would set the day to
Last
,
Sunday
and the month to
March
. The time you select in the
o'clock
field depends on your time
zone. In Germany for instance, you would select
2
in the
Hour
field because Germany's
time zone is one hour ahead of GMT or UTC (GMT+1).
End rule
Configure the day and time when Daylight Saving Time ends if you enabled Daylight
Saving. You can select a specific date in a particular month or a specific day of a specific
week in a particular month. The
Time
field uses the 24 hour format. Here are a couple of
examples:
Daylight Saving Time ends in the United States on the first Sunday of November. Each
time zone in the United States stops using Daylight Saving Time at 2 A.M. local time. So
in the United States you would set the day to
First
,
Sunday
, the month to
November
and the time to
2
in the
Hour
field.
Daylight Saving Time ends in the European Union on the last Sunday of October. All of the
time zones in the European Union stop using Daylight Saving Time at the same moment
(1 A.M. GMT or UTC). So in the European Union you would set the day to
Last
,
Sunday
,
and the month to
October
. The time you select in the
o'clock
field depends on your time
zone. In Germany for instance, you would select
2
in the
Hour
field because Germany's
time zone is one hour ahead of GMT or UTC (GMT+1).
Page 265 / 367
Chapter 30 Time Settings
VMG4380-B10A / VMG4325-B10A User’s Guide
265
Apply
Click
Apply
to save your changes.
Cancel
Click
Cancel
to exit this screen without saving.
Table 105
Maintenance > Time Setting (continued)
LABEL
DESCRIPTION