Chapter 36 Diagnostic
eircom F1000 Modem User’s Guide
276
36.5
OAM Ping
Click
Maintenance > Diagnostic > OAM Ping
to open the screen shown next. Use this screen to
perform an OAM (Operation, Administration and Maintenance) F4 or F5 loopback test on a PVC. The
Device sends an OAM F4 or F5 packet to the DSLAM or ATM switch and then returns it to the
Device. The test result then displays in the text box.
ATM sets up virtual circuits over which end systems communicate. The terminology for virtual
circuits is as follows:
Figure 170
Virtual Circuit Topology
Think of a virtual path as a cable that contains a bundle of wires. The cable connects two points and
wires within the cable provide individual circuits between the two points. In an ATM cell header, a
VPI (Virtual Path Identifier) identifies a link formed by a virtual path; a VCI (Virtual Channel
Identifier) identifies a channel within a virtual path. A series of virtual paths make up a virtual
circuit.
F4 cells operate at the virtual path (VP) level, while F5 cells operate at the virtual channel (VC)
level. F4 cells use the same VPI as the user data cells on VP connections, but use different
predefined VCI values. F5 cells use the same VPI and VCI as the user data cells on the VC
connections, and are distinguished from data cells by a predefinded Payload Type Identifier (PTI) in
the cell header. Both F4 flows and F5 flows are bidirectional and have two types.
segment F4 flows (VCI=3)
end-to-end F4 flows (VCI=4)
segment F5 flows (PTI=100)
end-to-end F5 flows (PTI=101)
OAM F4 or F5 tests are used to check virtual path or virtual channel availability between two DSL
devices. Segment flows are terminated at the connecting point which terminates a VP or VC
segment. End-to-end flows are terminated at the end point of a VP or VC connection, where an ATM
link is terminated. Segment loopback tests allow you to verify integrity of a PVC to the nearest
neighboring ATM device. End-to-end loopback tests allow you to verify integrity of an end-to-end
PVC.
Note: The DSLAM to which the Device is connected must also support ATM F4 and/or F5
to use this test.
Virtual Channel (VC)
Logical connections between ATM devices
Virtual Path (VP)
A bundle of virtual channels
Virtual Circuits
A series of virtual paths between circuit end points
Page 277 / 359
Chapter 36 Diagnostic
eircom F1000 Modem User’s Guide
277
Note: This screen is available only when you configure an ATM layer-2 interface.
Figure 171
Maintenance > Diagnostic > OAM Ping
The following table describes the fields in this screen.
36.6
WAN Diagnostics Tests
Click
Maintenance > Diagnostic > WAN Diagnostics Tests
to open the screen shown next. Use
this screen to perform a test on the current WAN connection by clicking the
Wan Connection Test
button. The test result then displays in the text box.
Figure 172
Maintenance > Diagnostic > WAN Diagnostics Tests
Table 127
Maintenance > Diagnostic > OAM Ping
LABEL
DESCRIPTION
Select a PVC on which you want to perform the loopback test.
F4 segment
Press this to perform an OAM F4 segment loopback test.
F4 end-end
Press this to perform an OAM F4 end-to-end loopback test.
F5 segment
Press this to perform an OAM F5 segment loopback test.
F5 end-end
Press this to perform an OAM F5 end-to-end loopback test.
Page 278 / 359
Chapter 36 Diagnostic
eircom F1000 Modem User’s Guide
278
Page 279 / 359
eircom F1000 Modem User’s Guide
279
C
HAPTER
37
Troubleshooting
This chapter offers some suggestions to solve problems you might encounter. The potential
problems are divided into the following categories.
Power, Hardware Connections, and LEDs
Device Access and Login
Internet Access
Wireless Internet Access
USB Device Connection
UPnP
37.1
Power, Hardware Connections, and LEDs
The Device does not turn on. None of the LEDs turn on.
1
Make sure the Device is turned on.
2
Make sure you are using the power adaptor or cord included with the Device.
3
Make sure the power adaptor or cord is connected to the Device and plugged in to an appropriate
power source. Make sure the power source is turned on.
4
Turn the Device off and on.
5
If the problem continues, contact the vendor.
One of the LEDs does not behave as expected.
1
Make sure you understand the normal behavior of the LED. See
Section 1.5 on page 20
.
2
Check the hardware connections.
3
Inspect your cables for damage. Contact the vendor to replace any damaged cables.
4
Turn the Device off and on.
Page 280 / 359
Chapter 37 Troubleshooting
eircom F1000 Modem User’s Guide
280
5
If the problem continues, contact the vendor.
37.2
Device Access and Login
I forgot the IP address for the Device.
1
The default LAN IP address is 192.168.1.254.
2
If you changed the IP address and have forgotten it, you might get the IP address of the Device by
looking up the IP address of the default gateway for your computer. To do this in most Windows
computers, click
Start > Run
, enter
cmd
, and then enter
ipconfig
. The IP address of the
Default
Gateway
might be the IP address of the Device (it depends on the network), so enter this IP
address in your Internet browser.
3
If this does not work, you have to reset the device to its factory defaults. See
Section 1.6 on page
22
.
I forgot the password.
1
The default admin password is the wireless key printed on the back of the Device.
2
If this does not work, you have to reset the device to its factory defaults. See
Section 1.6 on page
22
.
I cannot see or access the
Login
screen in the web configurator.
1
Make sure you are using the correct IP address.
The default IP address is
192.168.1.254
.
If you changed the IP address (
Section 6.2 on page 105
), use the new IP address.
If you changed the IP address and have forgotten it, see the troubleshooting suggestions for
I
forgot the IP address for the Device.
2
Check the hardware connections, and make sure the LEDs are behaving as expected. See
Section
1.5 on page 20
.
3
Make sure your Internet browser does not block pop-up windows and has JavaScripts and Java
enabled. See
Appendix C on page 315
.
4
If it is possible to log in from another interface, check the service control settings for HTTP and
HTTPS (
Maintenance > Remote MGMT
).

Rate

3.5 / 5 based on 2 votes.