Page 271 / 359 Scroll up to view Page 266 - 270
Chapter 35 Configuration
eircom F1000 Modem User’s Guide
271
Reset to Factory Defaults
Click the
Reset
button to clear all user-entered configuration information and return the Device to
its factory defaults. The following warning screen appears.
Figure 165
Reset Warning Message
Figure 166
Reset In Process Message
You can also press the
RESET
button on the rear panel to reset the factory defaults of your Device.
Refer to
Section 1.6 on page 22
for more information on the
RESET
button.
35.3
The Reboot Screen
System restart allows you to reboot the Device remotely without turning the power off. You may
need to do this if the Device hangs, for example.
Click
Maintenance > Reboot
. Click
Reboot
to have the Device reboot. This does not affect the
Device's configuration.
Figure 167
Maintenance > Reboot
Page 272 / 359
Chapter 35 Configuration
eircom F1000 Modem User’s Guide
272
Page 273 / 359
eircom F1000 Modem User’s Guide
273
C
HAPTER
36
Diagnostic
36.1
Overview
The
Diagnostic
screens display information to help you identify problems with the Device.
The route between a CO VDSL switch and one of its CPE may go through switches owned by
independent organizations. A connectivity fault point generally takes time to discover and impacts
subscriber’s network access. In order to eliminate the management and maintenance efforts, IEEE
802.1ag is a Connectivity Fault Management (CFM) specification which allows network
administrators to identify and manage connection faults. Through discovery and verification of the
path, CFM can detect, analyze and isolate connectivity faults in bridged LANs.
36.1.1
What You Can Do in this Chapter
• The
Ping & TraceRoute & NsLookup
screen lets you ping an IP address or trace the route
packets take to a host (
Section 36.3 on page 274
).
• The
802.1ag
screen lets you perform CFM actions (
Section 36.5 on page 276
).
• The
OAM Ping
screen lets you send an ATM OAM (Operation, Administration and Maintenance)
packet to verify the connectivity of a specific PVC. (
Section 36.5 on page 276
).
36.2
What You Need to Know
The following terms and concepts may help as you read through this chapter.
How CFM Works
A Maintenance Association (MA) defines a VLAN and associated Maintenance End Point (MEP) ports
on the device under a Maintenance Domain (MD) level. An MEP port has the ability to send
Connectivity Check Messages (CCMs) and get other MEP ports information from neighbor devices’
CCMs within an MA.
CFM provides two tests to discover connectivity faults.
Loopback test - checks if the MEP port receives its Loop Back Response (LBR) from its target
after it sends the Loop Back Message (LBM). If no response is received, there might be a
connectivity fault between them.
Link trace test - provides additional connectivity fault analysis to get more information on where
the fault is. If an MEP port does not respond to the source MEP, this may indicate a fault.
Administrators can take further action to check and resume services from the fault according to
the line connectivity status report.
Page 274 / 359
Chapter 36 Diagnostic
eircom F1000 Modem User’s Guide
274
36.3
Ping & TraceRoute & NsLookup
Use this screen to ping, traceroute, or nslookup an IP address. Click
Maintenance > Diagnostic >
Ping&TraceRoute&NsLookup
to open the screen shown next.
Figure 168
Maintenance > Diagnostic > Ping &TraceRoute&NsLookup
The following table describes the fields in this screen.
Table 125
Maintenance > Diagnostic > Ping & TraceRoute & NsLookup
LABEL
DESCRIPTION
URL or IP
Address
Type the IP address of a computer that you want to perform ping, traceroute, or nslookup in
order to test a connection.
Ping
Click this to ping the IP address that you entered.
TraceRoute
Click this button to perform the traceroute function. This determines the path a packet
takes to the specified computer.
Nslookup
Click this button to perform a DNS lookup on the IP address of a computer you enter.
Page 275 / 359
Chapter 36 Diagnostic
eircom F1000 Modem User’s Guide
275
36.4
802.1ag
Click
Maintenance > Diagnostic
>
8.2.1ag
to open the following screen. Use this screen to
perform CFM actions.
Figure 169
Maintenance > Diagnostic > 802.1ag
The following table describes the fields in this screen.
Table 126
Maintenance > Diagnostic > 802.1ag
LABEL
DESCRIPTION
802.1ag Connectivity Fault Management
Maintenance
Domain (MD)
Level
Select a level (0-7) under which you want to create an MA.
Destination
MAC Address
Enter the target device’s MAC address to which the Device performs a CFM loopback test.
802.1Q VLAN
ID
Type a VLAN ID (0-4095) for this MA.
VDSL Traffic
Type
This shows whether the VDSL traffic is activated.
Loopback
Message (LBM)
This shows how many Loop Back Messages (LBMs) are sent and if there is any inorder or
outorder Loop Back Response (LBR) received from a remote MEP.
Linktrace
Message (LTM)
This shows the destination MAC address in the Link Trace Response (LTR).
Set MD Level
Click this button to configure the MD (Maintenance Domain) level.
Send Loopback
Click this button to have the selected MEP send the LBM (Loop Back Message) to a specified
remote end point.
Send Linktrace
Click this button to have the selected MEP send the LTMs (Link Trace Messages) to a
specified remote end point.

Rate

3.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top