Page 16 / 236 Scroll up to view Page 11 - 15
Chapter 1 Introduction
EMG2926-Q10A User’s Guide
16
Figure 4
Front Panel
The following table describes the LEDs and the WPS button.
Table 1
Front panel LEDs and WPS button
LED
STATUS
DESCRIPTION
WPS Button
Press this button for 1 second to set up a wireless connection via WiFi Protected Setup
with another WPS-enabled client. You must press the WPS button on the client side within
120 seconds for a successful connection. See
Section 1.6 on page 14
and
Section 6.2 on
page 48
for more information on WPS.
Power
On
The EMG2926-Q10A is receiving power and functioning properly.
Off
The EMG2926-Q10A is not receiving power.
WAN
On
The EMG2926-Q10A’s WAN connection is ready.
Blinking
The EMG2926-Q10A is sending/receiving data through the WAN with a
1000Mbps transmission rate.
Off
The WAN connection is not ready, or has failed.
Internet
On
The EMG2926-Q10A has an IP connection but no traffic.
Your device has a WAN IP address (either static or assigned by a DHCP
server), PPP negotiation was successfully completed (if used) and the
connection is up.
Blinking
The EMG2926-Q10A is sending or receiving IP traffic.
Off
The EMG2926-Q10A does not have an IP connection.
WLAN 2.4/5G
On
The EMG2926-Q10A is ready, but is not sending/receiving data through the
5G wireless LAN.
Blinking
The EMG2926-Q10A is sending/receiving data through the 5G wireless LAN.
The EMG2926-Q10A is negotiating a WPS connection with a wireless client.
Off
The wireless LAN is not ready or has failed.
LAN 1-4
On
The EMG2926-Q10A’s LAN connection is ready.
Blinking
The EMG2926-Q10A is sending/receiving data through the LAN with a
1000Mbps transmission rate.
Off
The LAN connection is not ready, or has failed.
USB 1-2
On
The EMG2926-Q10A has a USB device installed.
Blinking
The EMG2926-Q10A is transmitting and/or receiving data from routers
through an installed USB device.
Off
There is no USB device connected to the EMG2926-Q10A.
Power
LAN 1-4
WAN
WPS
USB 1-2
WPS
Button
Internet
WLAN 5G
WLAN 2.4G
Page 17 / 236
Chapter 1 Introduction
EMG2926-Q10A User’s Guide
17
1.8
Wall Mounting
You may need screw anchors if mounting on a concrete or brick wall.
1
Select a position free of obstructions on a wall strong enough to hold the weight of the device.
2
Mark two holes on the wall at the appropriate distance apart for the screws.
Be careful to avoid damaging pipes or cables located inside the wall
when drilling holes for the screws.
3
If using screw anchors, drill two holes for the screw anchors into the wall. Push the anchors into the
full depth of the holes, then insert the screws into the anchors. Do not insert the screws all the way
in - leave a small gap of about 0.5 cm.
If not using screw anchors, use a screwdriver to insert the screws into the wall. Do not insert the
screws all the way in - leave a gap of about 0.5 cm.
4
Make sure the screws are fastened well enough to hold the weight of the EMG2926-Q10A with the
connection cables.
5
Align the holes on the back of the EMG2926-Q10A with the screws on the wall. Hang the EMG2926-
Q10A on the screws.
Figure 5
Wall Mounting Example
Table 2
Wall Mounting Information
Distance between holes
12.7 cm
M4 Screws
Two
Screw anchors (optional)
Two
Page 18 / 236
EMG2926-Q10A User’s Guide
18
C
HAPTER
2
Introducing the Web Configurator
2.1
Overview
This chapter describes how to access the EMG2926-Q10A Web Configurator and provides an
overview of its screens.
The Web Configurator is an HTML-based management interface that allows easy setup and
management of the EMG2926-Q10A via Internet browser. Use Internet Explorer 9.0 and later
versions, Mozilla Firefox 21 and later versions, Safari 6.0 and later versions or Google Chrome 26.0
and later versions. The recommended screen resolution is 1024 by 768 pixels.
In order to use the Web Configurator you need to allow:
Web browser pop-up windows from your device. Web pop-up blocking is enabled by default in
Windows XP SP (Service Pack) 2.
JavaScript (enabled by default).
Java permissions (enabled by default).
Refer to the Troubleshooting chapter (
Chapter 25 on page 175
) to see how to make sure these
functions are allowed in Internet Explorer.
2.2
Login Accounts
There are two system accounts that you can use to log in to the EMG2926-Q10A: “
admin
” and
supervisor
”. These two accounts have different privilege levels. The web configurator screens
vary depending on which account you use to log in.
The
supervisor
accounts allows you full access to all system configurations. The default supervisor
user name is “supervisor” and password is “supervisor”.
With the
admin
account, you cannot access
Remote MGMT
screens and can only view the
Sys OP
Mode screen
. The default username is “admin” and password is “1234”.
2.3
Accessing the Web Configurator
1
Make sure your EMG2926-Q10A hardware is properly connected and prepare your computer or
computer network to connect to the EMG2926-Q10A (refer to the Quick Start Guide).
2
Launch your web browser.
Page 19 / 236
Chapter 2 Introducing the Web Configurator
EMG2926-Q10A User’s Guide
19
3
The EMG2926-Q10A is in router mode by default. Type "http://192.168.1.1" as the website
address.
If the EMG2926-Q10A is in access point, the IP address is 192.168.1.2. See
Chapter 3 on page 22
for more information about the modes of the EMG2926-Q10A.
Your computer must be in the same subnet in order to access this website address.
2.3.1
Login Screen
The Web Configurator initially displays the following login screen.
If you are logging in with the “
admin
” account, type “1234” (default) as the password.
If you are logging in with the “
supervisor
” account, type “supervisor” (default) as the password.
Then click
Login
.
Figure 6
Login screen
The following table describes the labels in this screen.
Table 3
Login screen
LABEL
DESCRIPTION
Language
Select the language you want to use to configure the Web Configurator.
User
Type “supervisor” or "admin" (default) as the user name.
Password
Type “supervisor” or "1234" (default) as the password. Click
Login
.
This shows the current weather, either in celsius or fahrenheit, of the city you specify in
Section 2.3.2.1 on page 20
.
This shows the time (hh:mm:ss) and date (yyyy:mm:dd) of the timezone you select in
Section 24.5 on page 166
. The time is in 24-hour format, for example 15:00 is 3:00 PM.
Page 20 / 236
Chapter 2 Introducing the Web Configurator
EMG2926-Q10A User’s Guide
20
2.3.2
Password Screen
You should see a screen asking you to change your password (highly recommended) as shown
next.
Figure 7
Change Password Screen
The following table describes the labels in this screen.
Note: The management session automatically times out when the time period set in the
Administrator Inactivity Timer
field expires (default five minutes; go to
Chapter
24 on page 164
to change this). Simply log back into the EMG2926-Q10A if this
happens.
2.3.2.1
Weather Edit
You can change the temperature unit and select the location for which you want to know the
weather.
Click the
icon to change the Weather display.
Figure 8
Change Weather
Table 4
Change Password Screen
LABEL
DESCRIPTION
New Password
Type a new password.
Retype to Confirm
Retype the password for confirmation
.
Apply
Click
Apply
to save your changes back to the EMG2926-Q10A.
Ignore
Click
Ignore
if you do not want to change the password this time.

Rate