Page 36 / 131 Scroll up to view Page 31 - 35
User Manual for T2-B-Gawv1.4U10Y.BI
Teracom Limited
33
An ISO Certificed Company
Sample 1: PPP over ATM (PPPoA)
Step 1
Select
PPP over ATM (PPPoA)
protocol and set the encapsulation type
to
VC MUX
(depending upon the uplink equipment, generally
VC MUX
).
Then click
Next
.
Page 37 / 131
User Manual for T2-B-Gawv1.4U10Y.BI
Teracom Limited
34
An ISO Certificed Company
Step 2
In this example, the modem must be configured as built-in PPPoA + NAT.
Select
Obtain an IP address automatically
,
Enable NAT
, and
Add
Default Route
.
The following table describes the parameters of this page.
Field
Description
Obtain an IP address
automatically
Through PPP dial-up to obtain an IP address
assigned by up-link equipment, such as
BRAS.
Use
the
following
IP
address
If you want to manually enter the WAN IP
address, select it and enter the IP address
provided by your ISP.
Enable NAT
Select
it
to
enable
network
address
translation (NAT) function of the modem. If
you do not enable NAT and want to the
modem to access the Internet normally, you
must add a route on the uplink equipment.
Otherwise, the access to the Internet fails.
Normally, it is required to enable NAT.
Add Default Route
Add a default route in the routing table.
Normally, it must be selected. Otherwise, you
have to add a default route manually.
Step 3
Enter the correct broadband user name and password. Select a proper
PPP connection mode. Then click
Next
.
Page 38 / 131
User Manual for T2-B-Gawv1.4U10Y.BI
Teracom Limited
35
An ISO Certificed Company
The following table describes the parameters of this page.
Field
Description
Broadband User Name
Enter the correct user name provided by your
ISP.
Password
Enter the correct password provided by your
ISP.
Confirm Password
Confirm the correct password provided by
your ISP.
Session established by
Select a PPP connection mode according to
your practice.
°
Always On
: After the device is powered
on, the system performs PPP dial-up
automatically. If the device is powered
off, DSLAM or the up-link equipment is
abnormal, the PPP connection will not be
broken.
°
Dial on Demand
: After the device is
powered on, the PPP dial-up performs
automatically. If the device does not
Page 39 / 131
User Manual for T2-B-Gawv1.4U10Y.BI
Teracom Limited
36
An ISO Certificed Company
Field
Description
detect the flow of the user continuously
within the preset minutes, the device
automatically stops the PPP connection.
Once the device detects the data flow
(for example, accessing the web page), it
restarts the PPP for dial-up.
°
Manually
Connect
:
Choose
Configuration
>
Internet Connection
>
Connections
. Click
Connect
in the
Internet
Connection
Configuration
page to start the PPP connection. If the
device does not detect the data-flow of
the user continuously within the preset
minutes,
the
device
automatically
releases
the
PPP
connection.
The
difference between manually connect
and dial on demand is that you must start
a PPP connection manually again if you
select
manually
connect.
Enter
the
waiting time in the field.
Step 4
Click
Next
and the following page appears. In this page, you can confirm
the modification.
Page 40 / 131
User Manual for T2-B-Gawv1.4U10Y.BI
Teracom Limited
37
An ISO Certificed Company
Check the configuration according to the requirements. When you ensure that the
configuration is correct, click
Apply
. The following page appears.