Page 71 / 88 Scroll up to view Page 66 - 70
Page 70
There are three Ethernet ports; one for each of the LAN, DMZ, and WAN ports:
Link
Lights up when the
Twisted Pair
port is connected to a 10Mbps or 100Mbps hub or switch,
or directly connected to a computer. Note that the connected Ethernet device must support
the standard Link Integrity test.
100
Lights up when the
Twisted Pair
port is connected to a 100Mbps hub or switch or directly
connected to a computer with a 100Mbps network interface.
Activity
Flashes when the SonicWALL PRO 100 transmits or receives a packet through the
Twisted
Pair
port.
SonicWALL PRO 100 Back Panel
The SonicWALL PRO 100 back panel is shown below, followed by a description of each item.
The SonicWALL PRO 100 Back Panel Description
Reset Switch
Erases the firmware and resets SonicWALL PRO 100 to its factory clean state. This can be
necessary if the administrator password is forgotten, or the firmware has become corrupt.
Instructions for erasing the SonicWALL firmware are Guide.
Serial
DB-9 RS-232 Serial port.
(3) Twisted Pair (10Base-T, 100Base-T) Ethernet Ports
(3) Auto switching 10Mbps/100Mbps Ethernet ports provide connectivity for both Ethernet
and Fast Ethernet networks. The Ethernet ports connect the SonicWALL PRO 100 to the
LAN, DMZ, and WAN using Twisted Pair cable with RJ45 connectors.
10Mbps/100Mbps
DMZ Ethernet Port
Reset Switch
10Mbps/100Mbps
LAN Ethernet Port
10Mbps/100Mpbs
WAN Ethernet Port
5VDC,2A
Power input
Cooling Vents
RS-232
Serial Port
Page 72 / 88
SonicWALL Installation Guide Page 71
Power Input
Connects to the external power supply that is provided with the SonicWALL PRO 100. The
use of an Uninterruptible Power Supply (UPS) is recommended to protect the SonicWALL
PRO 100 against damage or loss of data due to electrical storms, power failures, or power
surges.
Cooling Vents
The SonicWALL PRO 100 is convection cooled; an internal fan is not necessary. Do not
block the cooling vents.
SonicWALL SOHO3 and TELE3 Front Panel
The SonicWALL
SOHO3
front panel is shown below, followed by a description of each item.
The SonicWALL
TELE3
is identical to the SonicWALL
SOHO3
except for the
TELE3
label on
the front panel and the inclusion of SonicWALL VPN.
SonicWALL SOHO3 and SonicWALL TELE3 Front Panel Description
Power
Lights up when power is applied to the SonicWALL SOHO3 or SonicWALL TELE3.
Test
Lights up when the SonicWALL is first powered up and performing diagnostic tests to check
for proper operation. These tests take about 90 seconds. If the Test LED remains lit after
this time, the software is corrupt and must be reinstalled.
Power LED
WAN Port LEDs
Link, 100, Activity
LAN Port LEDs
Link, 100, Activity
Test LED
Page 73 / 88
Page 72
There are two Ethernet ports; one of the following for the LAN and WAN ports:
Link
Lights up when the Twisted Pair port is connected to a 10Mbps or 100Mbps hub or switch
or directly connected to a computer. Note that the connected Ethernet device must support
the standard Link Integrity test.
100
Lights up when the Twisted Pair port is connected to a 100Mbps hub or switch or directly
connected to a computer with a 100Mbps network interface.
Activity
Flashes when the SonicWALL transmits or receives a packet through the Twisted Pair port.
SonicWALL SOHO3 and TELE3 Back Panel
The SonicWALL SOHO3 back panel is shown below, followed by a description of each item. The
SonicWALL TELE3 back panel is identical to the SonicWALL SOHO3.
The SonicWALL SOHO3 and TELE3 Back Panel Description
Reset Switch
Erases the firmware and resets the SonicWALL to its factory clean state. This can be
necessary if you forget the administrator password or the firmware has become corrupt.
Serial Port
DB-9 RS-232 Serial port
Cooling Vents
Reset Switch
10Mbps/100Mbps
LAN Ethernet Port
10Mbps/100Mbps
WAN Ethernet Port
5VDC,2A
Power Input
RS-232
Serial Port
Page 74 / 88
SonicWALL Installation Guide Page 73
(2) Twisted Pair (10Base-T, 100Base-T) Ethernet Ports
(2) Auto switching 10Mbps/100Mbps Ethernet ports provide connectivity for both Ethernet
and Fast Ethernet networks. The Ethernet ports connect the SonicWALL to the LAN and
WAN using Twisted Pair cable with RJ45 connectors.
Power Input
Connects to the external power supply which is provided with the SonicWALL SOHO3 and
the SonicWALL TELE3. The use of an Uninterruptible Power Supply (UPS) is recommended
to protect against damage or loss of data due to electrical storms, power failures, or power
surges.
Cooling Vents
The SonicWALL is convection cooled; an internal fan is not necessary. Do not block the
cooling vents on the SonicWALL SOHO3 or the TELE3 side panels.
SonicWALL GX 250 and GX 650 Front Panel
The SonicWALL GX 250 front panel is shown below, followed by a description of each item. The
SonicWALL GX 650 is identical to the SonicWALL GX 250 except for the GX 650 label on the
front panel and the types of network interfaces installed.
SonicWALL GX Models Front Panel Description
Power
Lights up green if both power supplies are functioning on the SonicWALL GX Models.
If it is red, one of the power supplies has failed, and an audible alarm also sounds.
Power LED
Test LED
Reset Button
Serial Cable Port
Slot 1 Expansion
Slot 2
WAN
Slot 3
LAN
Slot 4
DMZ
Page 75 / 88
Page 74
Test
Lights up when the SonicWALL is powered up and performing diagnostic tests for
proper operation. These tests take up to 5 minutes. If the Test LED remains lit after
this time, the firmware is corrupt and must be reinstalled.
Serial
Port
DB-9 RS-232 Serial port for a modem or null-modem cable to support Command Line
Interface Management.
There are three network interfaces on the GX Models from left to right:
WAN
LAN
DMZ
The GX 250 includes two Fast Ethernet network interfaces.The GX 650 includes either Fast
Ethernet or 1000Base-SX over Fiber network interfaces. A fourth slot for upgrades is available
on the GX 250.
Two types of network cards are available in the GX series:
Fast Ethernet (10/100Base-T)
Gigabit over Fiber (1000Base-SX)
GX 250 Front Panel
Three Fast Ethernet interfaces provide connectivity for either Ethernet and Fast Ethernet
networks. The Ethernet ports connect the SonicWALL to the LAN, DMZ, and WAN using
category 5 twisted pair cable with RJ-45 connectors. There is an additional slot available for
upgrading the appliance. The standard NIC has two LEDs:
Link/Activity
The
Link
light is green when a twisted pair connection is made to another Ethernet
device (usually a switch or a hub) on the port. Note that the device connected to the
SonicWALL must support the standard link integrity test. The
Link
LED blinks,
indicating
Activity
, when the SonicWALL transmits or receives a packet through the
Twisted Pair port onto the network.
Network Speed
The
Network Speed
LED is not lit if the network speed is 10 Mbps, and the LED is
green if the network speed is 100 Mbps.
GX650 Front Panel
Three Gigabit over Fiber ports provide connectivity for Gigabit networks. Before inserting
the cables into the network ports on the fiber optics card, remove the plug from the ports.
The 1000Base-SX interface has the following LED lights:
Transmit (TX)
The
TX
light is lit when the network is transmitting data over the network connection.

Rate

4 / 5 based on 2 votes.

Popular SonicWALL Models

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top