4.5.9 VoIP Loop-Line Test
A VoIP loop-line test is used for locating a fault that occurs on wires A and B. It includes the
voltage test, resistance test, and current test.
Prerequisite
l
The user is a user with the operator authority or higher.
l
The OLT and the NMS communicate with each other properly.
l
The NMS is able to discover an online ONT and VoIP service parameters are configured.
Precautions
If a loop-line test is required in communication,
No Test
must be set to
Force
.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON Management
.
Step 3
In the window on the right, choose
GPON ONU
.
Step 4
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
Step 5
Select a required record from the ONT list, and then click the
The Ont's UNI Port Info
tab in
the lower pane.
Step 6
Select a record from the list whose
UNI Type
is
Pots
, right-click, and choose
Outer Line
Test
from the shortcut menu.
Step 7
In the dialog box that is displayed, set
Busy Processing
to
No Test
or
Force
, as shown in the
following figure.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
298