Page 296 / 364 Scroll up to view Page 291 - 295
Figure 4-9
Querying the status legends of a POTS port
----End
4.5.3 Querying the Status of a VoIP User
This topic describes how to verify VoIP service status by querying registration and calling states
of the VoIP user on the NMS.
Prerequisite
l
The user is a user with the operator authority or higher.
l
The OLT and the NMS communicate with each other properly.
l
The NMS is able to discover an online ONT and VoIP service parameters are configured.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON Management
.
Step 3
In the window on the right, choose
GPON ONU
.
Step 4
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
288
Page 297 / 364
Step 5
Select a required record from the ONT list, and then click the
POTS User
tab in the lower pane.
Step 6
View the user registration states in column
Status
and the user calling states in column
Call
Status
, as shown in the following figure.
Figure 4-10
Querying the status of a VoIP user
NOTE
The registration states and calling states are listed as follows:
l
Registration states include
Up
,
Initializing
,
Registering
,
Unregistering
,
Error
,
Testing
,
Quiescent
, and
Disabled
.
l
Calling states include
Idle
,
Calling
,
Ringing
,
Connecting
, and
InCall
.
----End
4.5.4 Querying and Deleting VoIP Statistics
VoIP statistics include RTP statistics and calling statistics. This topic describes how to query
and delete VoIP statistics.
Prerequisite
l
The user is a user with the operator authority or higher.
l
The OLT and the NMS communicate with each other properly.
l
The NMS is able to discover an online ONT and VoIP service parameters are configured.
Context
To query accurate VoIP statistics, delete the original VoIP statistics first.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON Management
.
Step 3
In the window on the right, choose
GPON ONU
.
Step 4
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
Step 5
Select a required record from the ONT list, and then click the
POTS User
tab in the lower pane.
Step 6
Query VoIP statistics.
1.
Select a record from the list, right-click, and then choose
Performance Statistic
.
2.
In the dialog box that is displayed, view the VoIP statistics, as shown in the following
figure.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
289
Page 298 / 364
Figure 4-11
Querying VoIP statistics
Step 7
Delete VoIP statistics.
1.
Select a record from the list, right-click, and then choose
Clear Performance Statistic
.
2.
In the dialog box that is displayed, click
Yes
.
3.
Perform step 2 to check whether VoIP statistics are deleted.
----End
4.5.5 Caller Emulation Test
The caller emulation test verifies the basic calling services and preliminarily locates a fault.
Prerequisite
l
The OLT and the NMS communicate with each other properly.
l
The NMS is able to discover an online ONT and VoIP service parameters are configured.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
290
Page 299 / 364
l
The user connected to the POTS port that is enabled with caller emulation successfully
registers with the softswitch.
Context
The call emulation test verifies the basic calling services during service provisioning, and works
with the POTS line test to preliminarily locate a fault.
There are three types of call emulation tests: caller emulation test, callee emulation test, and
automatic emulation test. The call emulation test is irrelevant to protocols for the upstream
transmission. That is, it is applicable to SIP and H.248.
After the POTS port is configured with parameters for the caller emulation test and is enabled
with the caller emulation test, the offhook and dialing emulation can be performed on the POTS
port. If the called number is correct and the callee is free, the phone of the caller is ringing. After
picking up the phone, the callee hears his/her own voice.
Impact on the System
After a POTS port is enabled with the caller emulation test, services carried on the POTS port
are interrupted. These services will be recovered after caller emulation is complete.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON Management
.
Step 3
In the window on the right, choose
GPON ONU
.
Step 4
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
Step 5
Select a required record from the ONT list, and then click the
The Ont's UNI Port Info
tab in
the lower pane.
Step 6
Select a record from the list whose
UNI Type
is
Pots
, right-click, and choose
Caller Emulation
Test
from the shortcut menu.
Step 7
In the dialog box that is displayed, set
Callee Number
, as shown in the following figure.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
291
Page 300 / 364
Figure 4-12
Caller emulation test
Step 8
Click
Start
.
----End
Result
After the caller emulation test is enabled, if the phone on the callee side (whose number is dialed
by the emulated caller) rings and the ringing is audible, the signaling connection is successful.
A test engineer answers the phone, and if the test engineer's voice can be heard on the receiver,
the media channel is available.
4.5.6 Callee Emulation Test
The callee emulation test verifies the basic calling services and preliminarily locates a fault.
Prerequisite
l
The OLT and the NMS communicate with each other properly.
l
The NMS is able to discover an online ONT and VoIP service parameters are configured.
l
The user connected to the POTS port that is enabled with callee emulation successfully
registers with the softswitch.
EchoLife HG8010/HG8110/HG8240/HG8245/HG8247/
HG8447 GPON Terminal
Service Manual
4 Maintenance and Troubleshooting
Issue 02 (2011-12-08)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
292

Rate