Context
The call emulation test verifies the basic calling services during service provisioning, and works
with the POTS line test to locate a fault.
There are three types of call emulation tests: caller emulation test, callee emulation test, and
automatic emulation test. The call emulation test is irrelevant to protocols for the upstream
transmission. That is, it is applicable to SIP and H.248.
After callee emulation is configured on the POTS port, the caller calls the callee and then is put
through to the callee automatically.
Impact on the System
l
After callee emulation is enabled on a POTS port, the callee cannot hear the dial tone after
offhook but hears mute. After the POTS port is enabled with callee emulation, services
carried on the POTS port are interrupted. These services will be recovered after callee
emulation is complete.
l
After a POTS port is enabled with callee emulation, if the user of this port is not called by
a caller, the user will exit callee emulation in three minutes. Within these three minutes,
the VoIP service and other services are interrupted.
Procedure
Step 1
In the
Physical Map
navigation tree on the
Main Topology
tab page, double-click the target
OLT, or select the target OLT, right-click, and choose
NE Explorer
.
Step 2
In the navigation tree, choose
GPON
>
GPON Management
.
Step 3
In the window on the right, choose
GPON ONU
.
Step 4
On the
GPON ONU
tab page, set the search criteria to find the GPON ONU records.
Step 5
Select a required record from the ONT list, and then click the
The Ont's UNI Port Info
tab in
the lower pane.
Step 6
Select a record from the list whose
UNI Type
is
Pots
, right-click, and choose
Callee Emulation
Test
from the shortcut menu.
Step 7
In the dialog box that is displayed, click
Start
, as shown in the following figure.
EchoLife HG8010/HG8240B/HG8245T/HG8247T GPON
Terminal
Service Manual
5 Maintenance and Troubleshooting
Issue 01 (2011-10-18)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.