Page 16 / 25 Scroll up to view Page 11 - 15
11
5
Configuring the HG520c
5.1
Changing the Administrator Password Used
for Logging In to the Web-Based Configuration
Utility
For safety reasons or to make the password easy to remember, you can change the
administrator password for login after logging in to the Web-based configuration
utility.
To change the password, do as follows:
Step 1
Log in to the Web-based configuration utility.
Step 2
Choose
Tools
>
System Management
in the navigation tree to display the
system management page.
Step 3
Click
to display a dialog box.
Step 4
Enter the old password in the and the
Old Password
text box. Enter the new
password in the
New Password
text box. Then enter the new password again
in the
Retype to confirm
text box for confirmation.
Step 5
Click
Submit
to save the settings.
After you change the password successfully, the current page jumps to the page for
logging in to the Web-based configuration utility. To log in to the Web-based
configuration utility, enter the new password, and then click
OK
.
If you forget the user name or password that has been changed, you can
restore the default settings of the HG520c by pressing and holding the
RESET button for over six seconds. Then, the user name and password
that are used for logging in to the Web-based configuration utility are
restored to default values. After you restore the default settings, however,
your customized data is lost. Therefore, use this function with caution.
5.2
Enabling or Disabling the Wireless
Network Function
You can quickly enable or disable the wireless network function by pressing the
WLAN button on the HG520c. To enable the wireless network function, press and hold
the WLAN button for over one second, and then release the button. You can disable the
Page 17 / 25
12
the
you can enable or disable the wireless network function through the
wireless network function, do
oose
Basic
>
Wireless Lan
.
Step 3
Select the
Enable
or
Disable
option button of
Access Point
.
wireless network function in the same way. The WLAN indicator shows whether
wireless network function is enabled.
In addition,
Web-based configuration utility. To enable or disable the
as follows:
Step 1
Log in to the Web-based configuration utility.
Step 2
In the navigation tree on the left, ch
Step 4
Click
Submit
to save the settings.
5.3
Changing the Wireless Network Name and
the Access Password
To change the name and access password for the wireless network, do as follows
th
n combo box.
mbo box.
Step 6
Enter an access password in the
Pre-Shared Key
text box.
(taking
e authentication type WPA-PSK as an example):
Step 1
Log in to the Web-based configuration utility.
Step 2
In the navigation tree on the left, choose
Basic
>
Wireless Lan
.
Step 3
Enter a wireless network name in the
SSID
text box.
Step 4
Select
WPA-PSK
from the
Authentication Type
drop-dow
Step 5
Select
TKIP
from the
Encryption
drop-down co
Step 7
Click
Submit
to save the settings.
5.4
Changing the IP Address Used for Logging
In to the Web-Based Configuration Utility
mber, you can change the IP address after
To change the IP address, do as follows:
the
Main IP Address
text box. Then,
enter a subnet mask in
Main Subnet Mask
.
Step 3
Click
Submit
to save the settings.
To make the login IP address easy to reme
logging in to the Web-based configuration utility.
Step 1
Choose
Basic
>
LAN Setting
in the navigation tree to display the LAN
settings page.
Step 2
Enter a new IP address as desired in
Page 18 / 25
13
To log in to the Web-based configuration utility after you change the IP
address successfully, you need to launch the Internet Explorer, and then
enter the new IP address in the address bar. Ensure that the IP address of
the computer is in the same network segment as that of the HG520c so
that the computer can access the Web-based configuration utility.
5.5
Restoring Default Settings
You can quickly restore the default settings of the HG520c by pressing the RESET
button on the rear panel. To restore the default settings, press and hold the RESET
button for over six seconds after the HG520c is powered on, and then release the button.
In addition, you can restore the default settings of the HG520c through the Web-based
configuration utility. To restore the default settings through the Web-based
configuration utility, do as follows:
Step 1
Log in to the Web-based configuration utility, and then choose
Tools
>
Reboot
in the navigation tree to display the reboot page.
Step 2
Select
Factory Default Settings
.
Step 3
Click
Restart
.
After the preceding operations, the current page jumps to the login page. You can log in
to the Web-based configuration utility by entering the default user name and password
that are
admin
.
6
FAQs
How can I quickly enable or disable the wireless network function?
Press and hold the WLAN button for over one second, and then release the button to
enable or disable the wireless network function. The WLAN indicator shows
whether the wireless network function is enabled.
How can I quickly restore the default settings of the terminal?
To restore the default settings, press and hold the RESET button on the rear panel
for over six seconds after the HG520c is powered on, and then release the button.
What can I do if I cannot access the Internet through the terminal?
Step 1
Check whether the POWER indicator on the terminal is solid on.
If the POWER indicator is off, perform further checks as follows:
1.
Ensure that the terminal is turned on.
2.
Ensure that electricity comes from the socket and that the power input
from the socket meets the requirements described on the label of the
Page 19 / 25
14
terminal power adapter. If the voltage is unsteady, for example, if the
voltage is too high or too low, do not use the terminal. Wait until the
voltage restores to its normal level, and then use the terminal.
3.
Ensure that the terminal is properly connected to the socket through
the power adapter.
If the POWER indicator is still off, contact an authorized maintenance
center.
Step 2
After powering on the terminal, wait for about three minutes. Then, check
whether the ADSL indicator on the terminal is solid on.
If the ADSL indicator blinks for a long time, perform further checks as
follows:
1.
Ensure that telephone lines are properly connected. Pay special
attention to the connections between the telephone lines and the
splitter.
2.
Ensure that the terminal or telephone lines are far from the electric
appliances that generate strong magnetic or electric fields. Replace
telephone lines when necessary.
If the ADSL indicator still blinks and does not turn solid on, contact your
network operator.
Step 3
Check whether the LAN indicator of the terminal is on.
If the LAN indicator is off, perform further checks as follows:
1.
Ensure that the network adapter of the computer is enabled.
2.
Ensure that the network cable between the terminal and the computer
is properly connected. Remove and then insert the network cable or
replace the network cable when necessary.
If the LAN indicator is still off, contact an authorized maintenance center.
Step 4
Check whether the driver for the network adapter is properly installed.
Take a computer that runs Windows XP as an example. To check whether
the driver for the network adapter is installed, do as follows:
1.
On the desktop, right-click
My Computer,
and then choose
Manage
.
2.
In the navigation tree of the
Computer Management
window,
choose
Device Manager
.
3.
In the right pane of the
Computer Management
window, click
Network adapters
to view the information about the network adapter
of the computer.
If no network adapter is found or if a question mark (?) or an exclamation
mark (!) is displayed next to the icon of the network adapter, you can infer
that the driver for the network adapter is not properly installed. In this
case, re-install the driver for the network adapter of the computer.
Page 20 / 25
15
Step 5
Ensure that you have entered the correct user name and user password that
are required by the PPP dial-up software.
The user name and the user password are provided by your network
operator.
Step 6
Check whether you can use the PPP dial-up software to dial successfully.
If you cannot use the PPP dial-up software to dial successfully, perform
further checks as follows:
1.
Stop the PPP dial-up software and then power off the terminal. After
five minutes, power on the terminal, and then use the PPP dial-up
software to dial again.
2.
Restore the default settings of the terminal.
If the problem persists, contact your network operator.
Step 7
Check whether the proxy server of the Web browser is correctly
configured. Take the Internet Explorer installed on a computer that runs
Windows XP as an example. To check whether the proxy server of the
Web browser is correctly configured, do as follows:
1.
Launch the Internet Explorer.
2.
Choose
Tools
>
Internet Options
.
3.
In the
Internet Options
dialog box, click the
Connections
tab.
4.
In the
Local Area Network (LAN) settings
group box, click
LAN
Settings
.
5.
In the
Proxy server
group box of the
Local Area Network (LAN)
Settings
dialog box, ensure that the
Use a proxy server for your
LAN (These settings will not apply to dial-up or VPN
connections).
check box is cleared.
Step 8
Try to access multiple Web sites to check whether the terminal can access
these Web sites.
If the terminal still cannot access Web sites, contact your network service
provider.
What can I do if Web pages often cannot be displayed during Web page browsing
and can be displayed after the terminal is restarted?
Step 1
Ensure that the terminal and other devices, such as telephones or fax
machines, are connected to telephone lines through a splitter.
For details about how to install a splitter, see the related description in the
manual.
Step 2
Ensure that telephone lines are properly connected.
If the telephone lines are improperly connected, the stability of the
network connection is affected.

Rate

4.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top