Page 61 / 92 Scroll up to view Page 56 - 60
59
GENERAL RULES FOR INSTALLATION
MY HOME
GUIDE
CONTROL
Telephone line
telephone
pair
ISP
My Home
system BUS
MHSERVER 2
CONNECTION THROUGH INTERNET
Connection through the Internet with a PSTN modem (only to send e-
mails through the modem)
This function uses the public telephone line and the WEB Server internal
modem to activate a temporary connection with the remote PC to send an
e-mail following events such as:
• burglar alarm system
• technical alarms
• call from the video door entry entrance panel.
The e-mails are sent to an electronic mail box, managed by an Internet
Service Provider (ISP), whose configuration parameters (POP server address,
login, and password) are specified in the TiWEB programme “Setup” section.
If the remote PC is configured to manage the e-mail via the Internet, the
user will be alerted in real time whenever the above-mentioned events
occur in his/her home.
The user will then be able to interact more with his/her home, establishing
the connection to the WEB Server and enabling, through Internet Explorer,
the display of the pictures sent by one of the video cameras installed in the
room involved.
Internet
www
www
CONNECTION THROUGH TELEPHONE LINE
Using the public telephone line and the WEB Server internal modem, a
Point-to-Point connection with a remote PC fitted with a modem can be
established.
The connection is established from the remote PC using the Windows
“remote access” function, specifying, instead of the Internet Service Provider
(ISP) telephone number, the telephone number to which the WEB Server
internal modem answers.
Telephone line
telephone
pair
Modem
My Home
system BUS
MHSERVER 2
Page 62 / 92
60
MY HOME - CONTROL
T
SCS
Ethernet
12V
Reset
F452
392100
230Va.c.
E46ADCN
SCS
Ethernet
12V
Reset
F452
392100
230Va.c.
SCS
Ethernet
12V
Reset
F452
392100
230Va.c.
SCS
Ethernet
12V
Reset
F452
NO
OK
NO
NO
F452 INSTALLATION RULES
Automation BUS
NOTE:
connect the Automation system power
supply item E46ADCN
and the WEB Server
power supply item 392100 to a common
two-pole switch.
The Ethernet cable should
not be a crossover
cable (pin to pin) if the WEB
Server is connected to a 10BASE T-type HUB. It should be a
crossover
cable
if the WEB Server is connected directly (point-to-point) to a PC. If the correct
cable is used, the green LED of the device will flash (more or less fast)
whenever network traffic is detected.
During the first installation and whenever the setting of the WEB Server or
the GSM module needs to be modified, the interface cable (item 335919)
needs to be connected to the PC serial port. The same cable will have to be
used in case of an upload of the setting already saved in the WEB Server or
in the GSM module and whenever the firmware is upgraded.
WARNINGS
• Installation and maintenance procedures shall be carried out by qualified
personnel only.
• Use insulated screwdrivers and do not touch the terminals to prevent
electrostatic discharges.
• Do not install the WEB Server or the GSM module near water (for example,
laundries, swimming pools, damp surfaces) or heat sources (radiators,
stoves, heaters).
• Do not install the device in particularly dusty places or in the presence of
corrosive vapours.
• Room temperature from +5° to +40°C, relative humidity ranging between
20% and 80%, non-condensating.
The WEB Server installation requires a connection:
-
to the mains by means of a dedicated power supply item 346000 (for
item F452V) or item 392100 (for item F452);
-
to the video camera(s) of the CCTV system (only for WEB Server item
F452V);
- to the automation system bus;
-
to the 10BASE T Ethernet communication network.
The GSM module installation requires a connection:
-
to the mains by means of a dedicated power supply item 392100
- to the automation system BUS;
-
to the GSM network by inserting the SIM Card in the appropriate housing
INSTALLATION AND MAIN OPERATIONS
1. Carry out wiring operations as described below and in the following page.
2. Install the TiServer programme (for items F452 and F452V) or the TiWEB
programme (for item MHGSM) on the PC which will be used for the
configuration. The PC should be connected to the WEB Server or the GSM
module through the serial port using item 335919 (please see the TiWEB
or TiServer user manual).
3. Define the static (fixed) IP address of the WEB Server and the Subnet
Mask of the Ethernet network to which the device will be connected (for
items F452 and F452V).
GENERAL RULES FOR INSTALLATION
F452, F452V and MHGSM
Page 63 / 92
61
GENERAL RULES FOR INSTALLATION
MY HOME
GUIDE
CONTROL
scs
±²H³RN³²
BC
A
D
rESET
±²³´µ
scs
±²H³RN³²
´
µ
´
µ
rESET
±²³´µ
¶²·¸¸¸
± ²
¹º»
±³´µ¶·¸·
NO
NO
BC
A
D
F452V INSTALLATION RULES
Carry out wiring operations in an orderly way
If a power supply feeding the SCS BUS is already present, do not connect the WEB SERVER to the BUS terminals of
item 346000.
Do not move devices which may cause
electromagnetic interferences close to the WEB
Server video
MHGSM INSTALLATION RULES
230Va.c.
OPEN
web
net
2
1
3
12V
IN
2
C
IN
1
SIM card
OPEN
web
net
2
1
3
12V
IN
2
C
IN
1
T
NO
OPEN
web
net
2
1
3
12V
IN
2
C
IN
1
SIM card
Do not move the BUS cable close
to the GSM antenna
Carry out wiring operations in an orderly way
NOTE:
connect the Automation
system power supply item
E46ADCN and the MHGSM
power supply item 392100 to a
common switch.
Automation BUS
Do not move devices
which may cause
electromagnetic
interferences close
to the MHGSM
Do not move the power
supplies of the Burglar
alarm and Automation
systems close to the
MHGSM
NOTE:
to ensure correct functioning, the device should be
installed in an area where the GSM signal of the chosen
telephone provider is good. For additional information on the
strength of the GSM signal or the use of an external antenna,
please see the Installation Manual.
WARNING:
antenna connection operations and the SIM card
insertion and removal must be carried out when the device is
not being supplied.
Page 64 / 92
62
MY HOME - CONTROL
2
1
2
3
4
5
6
7
8
9
0
OK
1
2
3
4
5
6
7
8
9
0
OK
3
3
1
1
The dialling device can be installed in any room in the home, in an easily
accessible area for easy modification of settings or reading of events.
The dialling device can be installed on the wall using the fastening plate.
GENERAL RULES FOR INSTALLATION- Burglar alarm control
unit with dialling device and telephone dialling device
Box 503
Telephone
line
SCS pair
Cable
fastening
hole
A
1
2
3
4
5
6
7
8
9
0
OK
1
2
3
4
5
6
7
8
9
0
OK
1
2
Fastening to the plate
To remove the dialling plate from
the plate lower the tab and push
upwards. A
Or flush-mounted in a Multibox switchboard
After establishing the exact point where the dialling device must be
installed set up the system; trunking for the passage of the cables for BUS
and telephone system, flush-mounting box and any finishings if installed in
MULTIBOX switchboards.
Before fastening it, make the connections as described in the technical
features – terminal board connection, insert and connect the back-up battery
in the compartment on the back and for installation in MULTIBOX move the
tamper jumper from -/T1 to - /T2.
Installation kit
complete
with frames
Pair for BTicino BUS (item L4669S)
Flush-mounting
box
Telephone
line
NOTE:
detailed information on the installation in Multibox switchboards can be
found in the instruction sheets with the switchboards themselves.
Page 65 / 92
63
GENERAL RULES FOR INSTALLATION
MY HOME
GUIDE
CONTROL
USABLE CABLE
The sheathed, non-shielded, twisted telephone pair or the red BTicino SCS
pair for burglar alarm system (item L4669S) should be used to connect the
device. The power supply, the operating signals and the alarm signals are
distributed through this pair.
Interrupting or sabotage of the connections
causes an immediate system alarm.
The BTicino pair (Item L4669) is 300/500V insulated and therefore can be
tubed with 230V a.c. cables
Telephone pair
SCS red pair
for burglar alarm
system (item L4669S)
BACK-UP BATTERY
Connect the battery Item 3507/6 to the connector in the compartment
on the back of the dialling device, after the battery has been put in the
compartment itself and then connect to the BUS, to avoid the battery
discharging uselessly.
Back-up battery connection
POSITION IN THE SYSTEM
The telephone dialling device must be the first component of the internal
telephone system: it must be connected immediately downstream of the line
Example of the connection of the telephone dialling device inside a home.
protection fuses and of the surge arrester.
Item 3507/6
Fuse
Discharge
Dialling device
Fax
Telephone
±
²
³
´
µ
·
¸
¹
º
ok

Rate

3.5 / 5 based on 2 votes.

Popular Bticino Models

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top