Page 6 / 47 Scroll up to view Page 1 - 5
Industry Canada Compliance
Under Industry Canada regulations, this radio transmitter may only operate using
an antenna of a type and maximum (or lesser) gain approved for the transmitter
by Industry Canada. To reduce potential radio interference to other users, the an-
tenna type and its gain should be so chosen that the equivalent isotropically radi-
ated power (e.i.r.p.) is not more than that necessary for successful communication.
This device complies with Industry Canada license-exempt RSS standard(s). Oper-
ation is subject to the following two conditions: (1) this device may not cause in-
terference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
For Mexico
The operation of this equipment is subject to the following two conditions: (1) This
equipment or device cannot cause harmful interference and (2) this equipment or
device must accept any interference, including interference that may cause some
unwanted operation of the equipment.
Touchstone DG860 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
6
Page 7 / 47
European Compliance
This product complies with the provisions of the Electromagnetic Compatibility
(EMC) Directive (89/336/EEC), the Amending Directive (92/31/EEC), the Low Volt-
age Directive (73/23/EEC), and the CE Marking Directive (93/68/EEC). As such,
this product bears the CE marking in accordance with the above applicable Direc-
tive(s).
A copy of the Declaration of Conformity may be obtained from: ARRIS Interna-
tional, Inc., 3871 Lakefield Drive, Suite 300, Suwanee, GA 30024.
As indicated by this symbol, disposal of this product is governed
by Directive 2002/96/EC of the European Parliament and of the
Council on waste electrical and electronic equipment (WEEE).
WEEE could potentially prove harmful to the environment; as
such, upon disposal of the Data Gateway the Directive requires
that this product must not be disposed as unsorted municipal
waste, but rather collected separately and disposed of in accor-
dance with local WEEE ordinances.
This product complies with directive 2002/95/EC of the European
Parliament and of the Council of 27 January 2003 on the restriction
of the use of certain hazardous substances (RoHS) in electrical and
electronic equipment.
Touchstone DG860 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
7
Page 8 / 47
Getting Started
About Your New Data Gateway
The Touchstone DG860 Data Gateway is DOCSIS compliant with the following fea-
tures:
Speed: much faster than dialup or ISDN service; up to eight times faster
than DOCSIS 2.0 cable modems.
Convenience: supports Ethernet and 802.11b/g/n wireless connections; both
can be used simultaneously
Compatibility: DOCSIS 3.0 compliant and backward-compatible with DOC-
SIS 2.0 or 1.1; supports tiered data services (if offered by your cable
company)
The DG860 provides:
Wireless 802.11b/g/n connectivity
Four Ethernet ports for connections to non-wireless devices
DG860A: DOCSIS 3.0 compliant
What’s in the Box?
Make sure you have the following items before proceeding. Call your cable company
for assistance if anything is missing.
Data Gateway
Power Cord
Wall-Mounting Template and Instructions
Quick Installation Guide
Ethernet Cable
Mini CD-ROM (80mm)
Note
: An adapter is required for slot-loading drives. Adapter is not included.
End User License Agreement
Touchstone DG860 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
8
Page 9 / 47
Coax Cable
9
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
Touchstone DG860 Data Gateway User’s Guide
What’s on the CD?
The CD provides the following items:
Quick Install Guide
User’s Guide
Items You Need
If you are installing the Data Gateway yourself, make sure you have the following
items on hand before continuing:
Data Gateway package
: see
What’s in the Box?
for a list of items in the
package.
Coaxial cable (coax)
: as shown in the image to the left, this is a round
cable with a connector on each end. It is the same kind of wire used to con-
nect to your television for cable TV. You can buy coax from any electronics
retailer and many discount stores; make sure it has connectors on both
ends. There are two types of connectors, slip-on and screw-on; the screw-
on connectors are best for use with your Data Gateway. The coax should be
long enough to reach from your Data Gateway to the nearest cable outlet.
Note:
For best performance, use high-quality RG-6 type coax cable and min-
imize or eliminate splitters between the cable jack and the Data Gateway.
Splitter (optional)
: provides an extra cable connection by splitting a sin-
gle outlet into two. You may need a splitter if you have a TV already con-
nected to the cable outlet that you want to use. You can buy a splitter from
any electronics retailer and most discount stores; you may also need a short
piece of coax cable (with connectors); use it to connect the splitter to the
cable outlet and then connect the Data Gateway and TV to the splitter.
Note
: A splitter effectively cuts the signal in half and sends each half to its
two outputs. Using several splitters in a line may deteriorate the quality of
your television, telephone, and/or internet connection.
Wall-mount hardware (optional)
: if you want to wall-mount your Data
Gateway, you need to obtain two drywall anchors or wood screws. See the
Wall-Mount Template and Instructions for more details.
Page 10 / 47
Information packet
: your cable company should furnish you with a packet
containing information about your service and how to set it up. Read this in-
formation carefully and contact your cable company if you have any ques-
tions.
Getting Service
Before trying to use your new Data Gateway, contact your local cable company to
establish an Internet account. When you call, have the following information ready:
the Data Gateway serial number and cable MAC addresses of the unit
(printed on a sticker on the bottom of the Data Gateway)
the model number of the Data Gateway
If the Data Gateway was provided by your cable company, they already have the
required information.
In addition, you should ask your cable company the following questions:
Do you have any special system requirements or files that I need to down-
load after I am connected?
When can I start using my Data Gateway?
Do I need a user ID or password to access the Internet or my e-mail?
Touchstone DG860 Data Gateway User’s Guide
Safety
Getting
Started
Installation
Ethernet
Configuration
Usage
Troubleshooting
Glossary
10

Rate

4 / 5 based on 1 vote.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top