Page 741 / 944 Scroll up to view Page 736 - 740
Chapter 47 File Manager
ZyWALL USG 50 User’s Guide
741
The following table describes the labels in this screen.
Table 234
Maintenance > File Manager > Configuration File
LABEL
DESCRIPTION
Rename
Use this button to change the label of a configuration file on the ZyWALL.
You can only rename manually saved configuration files. You cannot
rename the
lastgood.conf
,
system-default.conf
and
startup-
config.conf
files.
You cannot rename a configuration file to the name of another
configuration file in the ZyWALL.
Click a configuration file’s row to select it and click
Rename
to open the
Rename File
screen.
Figure 431
Maintenance > File Manager > Configuration File >
Rename
Specify the new name for the configuration file. Use up to 25 characters
(including a-zA-Z0-9;‘~!@#$%^&()_+[]{}’,.=-).
Click
OK
to save the duplicate or click
Cancel
to close the screen
without saving a duplicate of the configuration file.
Remove
Click a configuration file’s row to select it and click
Remove
to delete it
from the ZyWALL. You can only delete manually saved configuration
files. You cannot delete the
system-default.conf
,
startup-config.conf
and
lastgood.conf
files.
A pop-up window asks you to confirm that you want to delete the
configuration file. Click
OK
to delete the configuration file or click
Cancel
to close the screen without deleting the configuration file.
Download
Click a configuration file’s row to select it and click
Download
to save
the configuration to your computer.
Page 742 / 944
Chapter 47 File Manager
ZyWALL USG 50 User’s Guide
742
Copy
Use this button to save a duplicate of a configuration file on the ZyWALL.
Click a configuration file’s row to select it and click
Copy
to open the
Copy File
screen.
Figure 432
Maintenance > File Manager > Configuration File >
Copy
Specify a name for the duplicate configuration file. Use up to 25
characters (including a-zA-Z0-9;‘~!@#$%^&()_+[]{}’,.=-).
Click
OK
to save the duplicate or click
Cancel
to close the screen
without saving a duplicate of the configuration file.
Table 234
Maintenance > File Manager > Configuration File (continued)
LABEL
DESCRIPTION
Page 743 / 944
Chapter 47 File Manager
ZyWALL USG 50 User’s Guide
743
Apply
Use this button to have the ZyWALL use a specific configuration file.
Click a configuration file’s row to select it and click
Apply
to have the
ZyWALL use that configuration file. The ZyWALL does not have to restart
in order to use a different configuration file, although you will need to
wait for a few minutes while the system reconfigures.
The following screen gives you options for what the ZyWALL is to do if it
encounters an error in the configuration file.
Figure 433
Maintenance > File Manager > Configuration File >
Apply
Immediately stop applying the configuration file
- this is not
recommended because it would leave the rest of the configuration blank.
If the interfaces were not configured before the first error, the console
port may be the only way to access the device.
Immediately stop applying the configuration file and roll back to
the previous configuration
- this gets the ZyWALL started with a fully
valid configuration file as quickly as possible.
Ignore errors and finish applying the configuration file
- this
applies the valid parts of the configuration file and generates error logs
for all of the configuration file’s errors. This lets the ZyWALL apply most
of your configuration and you can refer to the logs for what to fix.
Ignore errors and finish applying the configuration file and then
roll back to the previous configuration
- this applies the valid parts
of the configuration file, generates error logs for all of the configuration
file’s errors, and starts the ZyWALL with a fully valid configuration file.
Click
OK
to have the ZyWALL start applying the configuration file or click
Cancel
to close the screen
#
This column displays the number for each configuration file entry. This
field is a sequential value, and it is not associated with a specific
address. The total number of configuration files that you can save
depends on the sizes of the configuration files and the available flash
storage space.
Table 234
Maintenance > File Manager > Configuration File (continued)
LABEL
DESCRIPTION
Page 744 / 944
Chapter 47 File Manager
ZyWALL USG 50 User’s Guide
744
47.3
The Firmware Package Screen
Click
Maintenance > File Manager > Firmware Package
to open the
Firmware Package
screen. Use the
Firmware Package
screen to check your
current firmware version and upload firmware to the ZyWALL.
File Name
This column displays the label that identifies a configuration file.
You cannot delete the following configuration files or change their file
names.
The
system-default.conf
file contains the ZyWALL’s default settings.
Select this file and click
Apply
to reset all of the ZyWALL settings to the
factory defaults. This configuration file is included when you upload a
firmware package.
The
startup-config.conf
file is the configuration file that the ZyWALL is
currently using. If you make and save changes during your management
session, the changes are applied to this configuration file. The ZyWALL
applies configuration changes made in the Web Configurator to the
configuration file when you click
Apply
or
OK
. It applies configuration
changes made via commands when you use the
write
command.
The
lastgood.conf
is the most recently used (valid) configuration file
that was saved when the device last restarted. If you upload and apply a
configuration file with an error, you can apply lastgood.conf to return to
a valid configuration.
Size
This column displays the size (in KB) of a configuration file.
Last Modified
This column displays the date and time that the individual configuration
files were last changed or saved.
Upload
Configuration
File
The bottom part of the screen allows you to upload a new or previously
saved configuration file from your computer to your ZyWALL
You cannot upload a configuration file named
system-default.conf
or
lastgood.conf
.
If you upload
startup-config.conf
, it will replace the current
configuration and immediately apply the new settings.
File Path
Type in the location of the file you want to upload in this field or click
Browse ...
to find it.
Browse...
Click
Browse...
to find the .conf file you want to upload. The
configuration file must use a “.conf” filename extension. You will receive
an error message if you try to upload a fie of a different format.
Remember that you must decompress compressed (.zip) files before you
can upload them.
Upload
Click
Upload
to begin the upload process. This process may take up to
two minutes.
Table 234
Maintenance > File Manager > Configuration File (continued)
LABEL
DESCRIPTION
Page 745 / 944
Chapter 47 File Manager
ZyWALL USG 50 User’s Guide
745
Note: The Web Configurator is the recommended method for uploading firmware. You
only need to use the command line interface if you need to recover the
firmware. See the CLI Reference Guide for how to determine if you need to
recover the firmware and how to recover it.
Find the firmware package at www.zyxel.com in a file that (usually) uses the
system model name with a .bin extension, for example, “zywall.bin”.
The ZyWALL’s firmware package cannot go through the ZyWALL when you enable
the anti-virus
Destroy compressed files that could not be decompressed
option. The ZyWALL classifies the firmware package as not being able to be
decompressed and deletes it. You can upload the firmware package to the ZyWALL
with the option enabled, so you only need to clear the
Destroy compressed files
that could not be decompressed
option while you download the firmware
package. See
Section 29.2.1 on page 469
for more on the anti-virus
Destroy
compressed files that could not be decompressed
option.
The firmware update can take up to five minutes. Do not turn off or
reset the ZyWALL while the firmware update is in progress!
Figure 434
Maintenance > File Manager > Firmware Package
The following table describes the labels in this screen.
Table 235
Maintenance > File Manager > Firmware Package
LABEL
DESCRIPTION
Boot
Module
This is the version of the boot module that is currently on the ZyWALL.
Current
Version
This is the firmware version and the date created.
Released
Date
This is the date that the version of the firmware was created.
File Path
Type in the location of the file you want to upload in this field or click
Browse
...
to find it.
Browse...
Click
Browse...
to find the .bin file you want to upload. Remember that you
must decompress compressed (.zip) files before you can upload them.
Upload
Click
Upload
to begin the upload process. This process may take up to two
minutes.

Rate

4.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top