Page 11 / 165
Scroll up to view Page 6 - 10
Telsey telecommunications
External Interfaces and Connectors
3
MT500--SIEN12
Chapter 2
External Interfaces
and Connectors
CPVA 500 LED DESCRIPTION
CPVA 500 is equipped with a signaling LED set showing its operation status.
Namely signaling LEDs, listed from left to right, behave as the following table
explains.
Fig. 1 Front View
1
2
3
4
Tab. 1: CPVA 500 - Led Indication
Ref.
Led Denomination
Led Colour
Indication
1
PHONE 1
Green
It indicates activity on Phone 1 line [VoIP]
On
= LINE 1 is off-hook
Slow Blinking
= LINE 1 is registered on gatekeeper
Fast Blinking
= LINE 1 is receiving a telephone call
Off
= No registration (line out of service)
2
PHONE 2
Green
It indicates activity on Phone 2 line [VoIP]
On
= LINE 2 is off-hook
Slow Blinking
= LINE 2 is registered on gatekeeper
Fast Blinking
= LINE 2 is receiving a telephone call
Off
= No registration (line out of service)
3
LINK
Amber
ADSL Uplink active on the port towards network
On
= ADSL Link avaliable (solid ON)
Off
= ADSL Link not avaliable (device out of service)
Slow Blinking
= Seeking Phase
Fast Blinking
= Training Phase
Blinking
= Traffic activity
4
POWER
Red
Power On/Off
Page 12 / 165
Telsey
telecommunications
External Interfaces and Connectors
MT500--SIEN12
4
CPVA 500 CONNECTORS DESCRIPTION
Fig. 2 CPVA 500 Connectors description
1
2
3
4
5
6
Tab. 2: CPVA 500 - Connection Indication
Port
Number
Function
Indication
Remarks
1
ADSL IN
ADSL Uplink Port with RJ11 connector
To ADSL WAN Uplink
2
ETHERNET
ETHERNET 10/100 BaseTX with RJ45 connector
Connect to user device [PC] through CAT5 cable
3
USB
USB B type port - v. 1.1, 12Mbps
Connect to user device [PC] through USB cable
4
PHONE 1
FXS with RJ11 connector
Connect to user analogue telephone through
phone cable
5
PHONE 2
FXS with RJ11 connector
Connect to user analogue telephone through
phone cable
6
12 Vdc
Power Supply Input
Use the provided Power Supplier
Page 13 / 165
Telsey telecommunications
Installation
5
MT500--SIEN12
Chapter 3
Installation
GENERAL ADVICES AND SECURITY RULES
Install the Access Gateway in a room with a temperature ranging between 5°C
and 45°C, and a relative humidity ranging from 5% to 85%. It is recommended
to avoid abrupt changes of temperature and humidity.
Leave a 10-15 cm of space around the Access Gateway in order to allow correct
aeration. Do not expose to direct sunlight. The device has to always be
connected to the electrical network. In order to avoid fire or electrical shock,
do not install it in a wet or humid environment.
Do not defuse any parts of the Access Gateway. Do not execute operations on
the internal parts for security reason. Do not insert any object into the
Access
Gateway. Use only the wall adapter present in the package and the original
spare parts. The socket outlet shall be installed near the equipment and shall
be easily accessible.
Ask for experienced assistance for any type of repair.
Do not cover the Serial Number and Mac Address label. The Serial Number and
the Mac Address will be requested during any call to the Customer Service.
Page 14 / 165
Telsey
telecommunications
Installation
MT500--SIEN12
6
CPVA 500 PLACEMENT
CPVA500 can be positioned in a place compatibled with cable length and where
the airflow is enough to cool off the equipment.
CPVA500 can be installed either on a flat or on a vertical surface (wall
placement).
In case of
table placement
, use the provided vertical or horizontal support.
Horizontal Support
Fig. 3 Table Placement - Horizontal Support
Vertical Support
Fig. 4 Table Placement - Vertical Support
Page 15 / 165
Telsey telecommunications
Installation
7
MT500--SIEN12
It is possible to place the Access Gateway on the wall by using the appropriate
support (provided) and screw-anchors (not provided, we suggest to use two
Fischer S4 screw anchors).
Wall Support
Fig. 5 Wall Placement: Wall Support