Page 16 / 120 Scroll up to view Page 11 - 15
LTE/WiMAX DM Outdoor | User Manual
Dual Mode CPE7000 Manual
16
16
Outdoor Connection:
Connect a grounding cable between the Ground terminal of the
WiMAX / LTE outdoor CPE and a good ground connection.
Preparing and connecting the cable:
Use only UTP-FTP 4x2x24AWG CAT. 5E outdoor cable
from an approved manufacturer. The cable provides pin-to-pin connection on both ends.
1.
Prepare the cable:
Use a crimp too for RJ-45 connectors to prepare the wires. Insert
them into the appropriate pins and use the tool to crimp the connector. Make sure to do
the following:
Remove as small a length as possible of the external jacket. Verify that the external
jacket is well inside the sealing cover when connected to the unit, to ensure good
sealing.
Pull back the shield drain wire before inserting the cable into the RJ-45 connector,
to ensure a good connection with the connector
s shield after crimping.
The following figure shows the required wire pair connections. The color codes used in
standard cables supplied by the manufacturer are as listed in the following table.
Page 17 / 120
LTE/WiMAX DM Outdoor | User Manual
Dual Mode CPE7000 Manual
17
17
2.
Connect the cable
Remove the sealing cable gland plug from the gland nut.
Open the sealing gland nut and remove it. Don not disassembles the gland base from
the bracket.
Insert the cable into the sealing gland base and connect it to the RJ-45 connector at
the bottom of the CPE. Make sure the connector is completely inserted and
tightened.
Insert the rubber bushing on the cable into the gland base.
Tighten the gland nut. Use the dedicated tool for fastening the sealing glands.
3.
Seal the connector
Attach the mastic tape (Scotchfil
TM
Electrical Insulation Putty) and wrap it around the
connector butting up against the connector. Do not over stretch.
Squeeze to tighten the mastic sealer. Make sure there are no air bubbles.
Slide the cold shrink sleeve on top of the connector. Make sure that the sleeve covers
both cable connector and unit connector.
Page 18 / 120
LTE/WiMAX DM Outdoor | User Manual
Dual Mode CPE7000 Manual
18
18
Pull the cord slowly to shrink the sleeve.
Indoor Connection
1.
It is assumed that the RJ-45 and telephone line cables are already connected to the
WiMAX / LTE outdoor CPE. Assemble an RJ-45 connector with a protective cover on the
other end of the WiMAX / LTE outdoor CPE cable.
2.
Connect the other end of the cable to the PoE adaptor which labeled
TO/FROM OSU
POE (RJ45)
.
3.
Connect telephone line cable from WiMAX / LTE outdoor CPE to PoE adaptor which
labeled
TO/FROM OSU VOIP (RJ14)
4.
Use a telephone cable to connect a phone to RJ-11 port on PoE adaptor with a
telephone illustration.
5.
Connect RJ45 cable from PoE adaptor to a PC/NB/Hub/Switch.
Page 19 / 120
LTE/WiMAX DM Outdoor | User Manual
Dual Mode CPE7000 Manual
19
19
Use
ONLY
the PoE adaptor which supplied with the ODU. Otherwise,
WiMAX / LTE outdoor CPE may be damaged.
Connect RJ45 from
ODU
Connect telephone line
from ODU
Page 20 / 120
LTE/WiMAX DM Outdoor | User Manual
Dual Mode CPE7000 Manual
20
20
Web Interface
Login to Web-GUI
User's devices are assumed to be connected to CPE LAN side. Please follow the steps below to
configure your device through WEB interface:
Step1:
Open the Web browser (Ex: Internet Explorer, Firefox or Chrome) and enter the default
IP address of CPE, which is :
Web browser
Step2:
Enter USERNAME/PASSWORD to access the web management interface. The default
USERNAME/PASSWORD of superuser is
operator / wimax.