Page 106 / 186 Scroll up to view Page 101 - 105
5-22
Linksys IP Phone Administrator Guide
Document Version 3.2
Chapter 5
Linksys ATA Field Reference
Regional Tab
Distinctive Ring/CWT Pattern Names
CWT6 Cadence
Cadence script for distinctive CWT 6.
The default is 30(.1/.1, .3/.1, .1/9.3).
CWT7 Cadence
Cadence script for distinctive CWT 7.
The default is 30(.1/.1, .3/.1, .1/9.3).
CWT8 Cadence
Cadence script for distinctive CWT 8.
The default is 2.3(..3/2).
Field
Description
Ring1 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 1 for the inbound
call.
The default is Bellcore-r1.
Ring2 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 2 for the inbound
call.
The default is Bellcore-r2
.
Ring3 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 3 for the inbound
call.
The default is Bellcore-r3
.
Ring4 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 4 for the inbound
call.
The default is Bellcore-r4
.
Ring5 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 5 for the inbound
call.
The default is Bellcore-r5
.
Ring6 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 6 for the inbound
call.
The default is Bellcore-r6
.
Ring7 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 7 for the inbound
call.
The default is Bellcore-r7
.
Ring8 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 8 for the inbound
call.
The default is Bellcore-r8
.
Page 107 / 186
5-23
Linksys IP Phone Administrator Guide
Document Version 3.2
Chapter 5
Linksys ATA Field Reference
Regional Tab
Ring and Call Waiting Tone Spec
Control Timer Values (sec)
Field
Description
Ring Waveform
Waveform for the ringing signal.
The default is Sinusoid.
Ring Frequency
Frequency of the ringing signal. Valid values are 10–100 (Hz).
The default is 25.
Ring Voltage
Ringing voltage. 60–90 (V).
The default is 70.
CWT Frequency
Frequency script of the call waiting tone. All distinctive CWTs are based on this tone.
The default is 440@-10.
Field
Description
Hook Flash Timer Min
Minimum on-hook time before off-hook qualifies as hook-flash. Less than this the
on-hook event is ignored. Range: 0.1–0.4 seconds.
The default is 0.1.
Hook Flash Timer Max
Maximum on-hook time before off-hook qualifies as hook-flash. More than this the
on-hook event is treated as on-hook (no hook-flash event). Range: 0.4–1.6 seconds.
The default is 0.9.
Callee On Hook Delay
Phone must be on-hook for at this time in sec before the Linksys IP phone will tear down
the current inbound call. It does not apply to outbound calls. Range: 0–255 seconds.
The default is 0.
Reorder Delay
Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =
never plays. Range: 0–255 seconds.
The default is 5.
Call Back Expires
Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
The default is 1800.
Call Back Retry Intvl
Call back retry interval in seconds. Range: 0–255 seconds.
The default is 30.
Call Back Delay
Delay after receiving the first SIP 18x response before declaring the remote end is
ringing. If a busy response is received during this time, the Linksys IP phone still
considers the call as failed and keeps on retrying.
The default is 0.5.
Page 108 / 186
5-24
Linksys IP Phone Administrator Guide
Document Version 3.2
Chapter 5
Linksys ATA Field Reference
Regional Tab
Vertical Service Activation Codes
Vertical Service Activation Codes are automatically appended to the dial-plan. There is
no
need to include them in dial-plan, although
no
harm is done if they are included.
VMWI Refresh Intvl
Interval between VMWI refresh to the CPE.
The default is 0.5.
Interdigit Long Timer
Long timeout between entering digits when dialing. The interdigit timer values are used
as defaults when dialing. The Interdigit_Long_Timer is used after any one digit, if all
valid matching sequences in the dial plan are incomplete as dialed. Range: 0–64 seconds.
The default is 10.
Interdigit Short Timer
Short timeout between entering digits when dialing. The Interdigit_Short_Timer is used
after any one digit, if at least one matching sequence is complete as dialed, but more
dialed digits would match other as yet incomplete sequences. Range: 0–64 seconds.
The default is 3.
CPC Delay
Delay in seconds after caller hangs up when the Linksys IP phone starts removing the
tip-and-ring voltage to the attached equipment of the called party. Range: 0–255 seconds.
Linksys IP phone has had polarity reversal feature since release 1.0 which can be applied
to both the caller and the callee end. This feature is generally used for answer supervision
on the caller side to signal to the attached equipment when the call has been connected
(remote end has answered) or disconnected (remote end has hung up). This feature should
be disabled for the called party (in other words, by using the same polarity for connected
and idle state) and the CPC feature should be used instead.
Without CPC enabled, reorder tone will is played after a configurable delay.
If CPC is enabled, dial tone will be played when tip-to-ring voltage is restored
Resolution is 1 second.
The default is 2.
CPC Duration
Duration in seconds for which the tip-to-ring voltage is removed after the caller hangs up.
After that, tip-to-ring voltage is restored and dial tone applies if the attached equipment
is still off-hook. CPC is disabled if this value is set to 0. Range: 0 to 1.000 second.
Resolution is 0.001 second.
The default is 0 (CPC disabled).
Field
Description
Call Return Code
This code calls the last caller.
The default is *69.
Call Redial Code
Redials the last number called. (Not in PAP2T)
The default is *07.
Blind Transfer Code
Begins a blind transfer of the current call to the extension specified after the activation
code.
The default is *98.
Page 109 / 186
5-25
Linksys IP Phone Administrator Guide
Document Version 3.2
Chapter 5
Linksys ATA Field Reference
Regional Tab
Call Back Act Code
Starts a callback when the last outbound call is not busy.
The default is *66.
Call Back Deact Code
Cancels a callback.
The default is *86.
Call Back Busy Act Code
Starts a callback when the last outbound call is busy. (Not in PAP2T)
The default is *05
Cfwd All Act Code
Forwards all calls to the extension specified after the activation code.
The default is *72.
Cfwd All Deact Code
Cancels call forwarding of all calls.
The default is *73.
Cfwd Busy Act Code
Forwards busy calls to the extension specified after the activation code.
The default is *90.
Cfwd Busy Deact Code
Cancels call forwarding of busy calls.
The default is *91.
Cfwd No Ans Act Code
Forwards no-answer calls to the extension specified after the activation code.
The default is *92.
Cfwd No Ans Deact Code
Cancels call forwarding of no-answer calls.
The default is *93.
Cfwd Last Act Code
Forwards the last inbound or outbound calls to the extension specified after the activation
code.
The default is *63.
Cfwd Last Deact Code
Cancels call forwarding of the last inbound or outbound calls.
The default is *83.
Block Last Act Code
Blocks the last inbound call.
The default is *60.
Block Last Deact Code
Cancels blocking of the last inbound call.
The default is *80.
Accept Last Act Code
Accepts the last outbound call. It lets the call ring through when do not disturb or call
forwarding of all calls are enabled.
The default is *64.
Accept Last Deact Code
Cancels the code to accept the last outbound call.
The default is *84.
CW Act Code
Enables call waiting on all calls.
The default is *56.
Page 110 / 186
5-26
Linksys IP Phone Administrator Guide
Document Version 3.2
Chapter 5
Linksys ATA Field Reference
Regional Tab
CW Deact Code
Disables call waiting on all calls.
The default is *57.
CW Per Call Act Code
Enables call waiting for the next call.
The default is *71.
CW Per Call Deact Code
Disables call waiting for the next call.
The default is *70.
Block CID Act Code
Blocks caller ID on all outbound calls.
The default is *67.
Block CID Deact Code
Removes caller ID blocking on all outbound calls.
The default is *68.
Block CID Per Call Act Code
Blocks caller ID on the next outbound call.
The default is *81.
Block CID Per Call Deact Code
Removes caller ID blocking on the next inbound call.
The default is *82.
Block ANC Act Code
Blocks all anonymous calls.
The default is *77.
Block ANC Deact Code
Removes blocking of all anonymous calls.
The default is *87.
DND Act Code
Enables the do not disturb feature.
The default is *78.
DND Deact Code
Disables the do not disturb feature.
The default is *79.
CID Act Code
Enables caller ID generation.
The default is *65.
CID Deact Code
Disables caller ID generation.
The default is *85.
CWCID Act Code
Enables call waiting, caller ID generation.
The default is *25.
CWCID Deact Code
Disables call waiting, caller ID generation.
The default is *45.
Dist Ring Act Code
Enables the distinctive ringing feature.
The default is *26
Dist Ring Deact Code
Disables the distinctive ringing feature.
The default is *46.

Rate