80
Specification
Video Specification
Resolution:
640 x 480 pixel
Sensor:
1/3” color CMOS sensor
Gain control:
Automatic
Exposure:
Automatic
White Balance:
Automatic
Shutter:
Electronics 1/60 ~ 1/15000 sec
Minimum Illumination:
[email protected], 3000K color
Focal Length:
6.0 mm
Aperture:
F=1.8
Focus Extent:
20 cm -
Lens mounting:
Fixed board lens, CS-mount type
Image (Video Setting)
Image compression:
JPEG
Frame rate:
30fps@QCIF, 20fps@CIF, 3fps@VGA
Compression Rate selection:
5 level (Very Low, Low, Medium, High,
Very High)
Frame rate setting:
1, 5, 7, 15, 20, auto (depends on the video
format)
Video resolution:
160x120, 320x240, 640x480
Brightness control:
Range 1- 128
Contrast control :
Range 1- 128
Hue control:
Range 1- 128
System Hardware
LAN Connector:
One RJ-45 port to connect to 10/100Mbps Ethernet,
auto-sensed
Generic I/O Port:
Four I/O ports, two for input and two for output
Total 8-pin:
Pin 1
Input Port (1)
Pin 2
Input Port (1)
Pin 3
Input Port (2)
Pin 4
Input Port (2)
Pin 5
Output Port (1+)
Pin 6
Output Port (1-)
Page 82 / 83
81
Pin 7
Output Port (2+)
Pin 8
Output Port (2-)
Note:
The output voltage is DC 5V and maximum current is 100mA.
LED Indicator:
Power LED (Blue)
LAN Activity LED (Orange)
Note:
LED three mode setting can be changed by software.
(Normal / Off / Dummy)
Power Supply:
DC 5V/2.4A, switching type
Power Communication: 4.5 Watt (900mA x 5V)
Communication Support
Communication:
10/100Mbps Ethernet only
Communication protocol: HTTP, FTP, TCP/IP, UDP, ARP,
ICMP, BOOTP, RARP, DHCP, PPPoE
Browser Support
Internet Explorer 5.0 or above (ActiveX & JAVA Mode – View
Image for Windows OS and JAVA Mode – View Image for other OS)
Netscape 6.0 or above (JAVA Mode – View Image)
CPU:
Pentium II, 266 MHz or above
Memory Size: 32 MB (64 MB recommended)
VGA card resolution: 800x600 or above
IPView Application
Win 98, Win 98 SE, Win 2000, Win Me, Win XP
Pentium III, 450 MHz or above
Memory Size of 128 MB (256 MB recommended)
VGA card resolution of 800x600 or above
Operating environment
Operating temperature:
5
~ 50
Storage temperature:
-25
~ 50
Humidity:
5% ~ 95% non-condensing
EMI
FCC , CE , VCCI
Page 83 / 83
82
Technical Support
D-Link provides free technical support for customers within the United States
during the warranty period. U.S. customers can contact D-Link Technical
Support through our web site, e-mail or by phone.
D-Link Technical Support over Telephone:
(949) 790-5290
6 a.m. to 6 p.m. Monday thru Friday
D-Link Technical Support over the Internet:
www.dlink.com
If you are a customer residing outside of the United States, please refer to the
list of D-Link locations that is included in the User’s Manual.
Registration
Register your DCS-1000 at

Rate

4.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top