Chapter 2 - Installation
Pole Mounting the ODU
11
2.2
Pole Mounting the ODU
2.2.1
Pole Mounting the ODU
The ODU can be mounted on a 1" to 4" pole using one of the following options:
A pole mounting kit is supplied with each unit. The kit includes a special clamp and a pair of threaded
rods, flat washers, spring washers and nuts. There are two pairs of threaded holes on the back of the
unit, enabling to use the mounting kit for installing the unit using either vertical or horizontal
polarization. The clamp enables installing the unit on diverse pole diameters from 1" to 4".
A Tilt Pole Mounting kit, providing a tilt range of +/-15° is available from Alvarion. The Tilt kit can be
attached to the ODU and be mounted on a 1" to 4" pole using two 9/16" wide metal bands.
1
Thread the M10*100 mm bolt through the M10 spring washer, M10 nut, and the bracket holes.
2
With the connector facing downward, attach the ODU to a 1"- 4" pole.
3
Attach the bracket to the other side of the pole.
4
Thread the M10*100 mm bolts through both holes on either side. Tighten the nuts.
To mount the ODU using the clamp:
Figure 2-1: Mounting the ODU on the Pole
Weather Proof Sealing Glands
Pole-Mount Bracket
M10*100 Bolts and spring
washers
Page 27 / 138
BreezeMAX PRO 6000
Product Manual
Chapter 2 - Installation
Pole Mounting the ODU
12
1
Attach the Tilt accessory to the ODU using the two pairs of flat washers, spring washers and nuts
supplied in the Tilt kit.
2
Mount the Tilt accessory on a 1" to 4" pole using two 9/16" metal bands.
3
Slightly release the Tilt Control Screw, tilt the ODU downward/upward as required, and re-tighten the
screw.
to mount the ODU using the Tilt accessory:
Figure 2-2: ODU Pole Installation Using the Tilt Accessory, Vertical Polarization
Tilt Control Screw
Tilt Accessory
Page 28 / 138
BreezeMAX PRO 6000
Product Manual
Chapter 2 - Installation
Connecting the ODU Cables
13
2.3
Connecting the ODU Cables
2.3.1
The PRO 6000 CPE Connectors
The PRO 6000 CPE has the following connectors:
One RJ-45 connector for connecting to the power injector indoor unit (ODU PoE
).
One Indoor /Outdoor connector (connects to GPS or used for distribution automation) (I / O, currently
not applicable)
A grounding screw on the rear panel.
The following figure illustrates the CPE connections:
Figure 2-3: CPE Connections
LEDs
ODU PoE
Input/Output serial
console (debug or
distribution automation
ODU
IDU
CAT 5 Ethernet cable
Page 29 / 138
BreezeMAX PRO 6000
Product Manual
Chapter 2 - Installation
Connecting the ODU Cables
14
2.3.2
Connecting the Grounding Cable
The Grounding screw (marked
) is located on the rear panel of the ODU.
1
Connect one end of a grounding cable to the grounding screw and tighten the grounding screw
firmly.
2
Connect the other end of the grounding cable to a good ground (earth) connection.
2.3.3
Connecting and Sealing the IDU-ODU PoE Cable
Use a crimp tool for RJ-45 connectors to prepare the wires. Insert them into the appropriate pins and use
the tool to crimp the connector. Make sure to do the following:
Remove as small a length as possible of the external jacket. Verify that the external jacket is well
inside the sealing cover when connected to the unit, to ensure good sealing.
Pull back the shield drain wire before inserting the cable into the RJ-45 connector to ensure a good
connection with the connector's shield after crimping.
The IDU-ODU cable provides pin-to-pin connection on both ends.
Figure 2-4: Rear View of the ODU
To connect the grounding cable:
CAUTION
Use only Category
5E 4x2x24# FTP outdoor cables from an approved manufacturer. See list of approved
cables in
Table 2-1
.The length of the Indoor-to-Outdoor cable should not exceed 90 meters. The length
of the Indoor-to-Outdoor cable, together with the length of the Ethernet cable connecting the IDU to
the data equipment, should not exceed 100 meters.
To prepare the IDU-ODU cable:
Grounding
Page 30 / 138
BreezeMAX PRO 6000
Product Manual
Chapter 2 - Installation
Connecting the ODU Cables
15
The following figure shows the required wire pair connections. The color codes used in standard cables
supplied by Alvarion are as listed in the table.
1
Remove the sealing gland plug from the gland nut.
2
Open the sealing gland nut and remove it.
Do not
disassemble the gland base from the bracket.
3
Insert the cable into the sealing gland base and connect it to the RJ-45 connector at the bottom of
the CPE, labeled
. Make sure that the connector is completely inserted and tightened.
4
Insert the rubber bushing on the cable into the gland base.
Wire color
Pin
Blue
1
Blue/white
2
Orange
3
Orange/white
6
Brown
4
Brown/white
5
Green
7
Green/white
8
Figure 2-5: Ethernet Connector Pin Assignments
To connect and seal the IDU-ODU cable:
Figure 2-6: Inserting the Cable into the Sealing Cap
Rubber Bushing
Sealing Gland Nut
Sealing Gland base