Page 121 / 132
Scroll up to view Page 116 - 120
Finding Solutions
117
4.
Click
System Log
; the
System Log
page opens.
5.
Click
Clear Log
if you want to minimize the clutter from previous events when you are trying to diagnose
a problem.
6.
Select from the
Select Device
drop-down list the hardware device you want to view.
7.
Filter the log category from the
Display Filter
drop-down list; the list is updated to your specification.
−
ALM for alarms
−
DBG for debug
−
EMR for emergency
−
ERR
for errors
−
FLT for faults
−
NTC for notice
−
INF
for information
−
WRN
for warning
Note:
The log starts from the oldest to the latest date; that is, the latest log
appears at the bottom of the page.
Page 122 / 132
iNID -- i3812V User Guide
118
8.
Click
Submit
; the page refreshes and displays the logs of your selection.
9.
Click
Insert Mark
if you want to insert a delimitation point in the logs.
10.
View the log.
−
Type
: The type of events:
ERR
for errors,
INF
for information,
WRN
for warning, and so forth.
−
Date/Time
: The date and time when the event occurs listing from the latest date on the top.
−
Event Description
: Includes a brief description of the event.
Viewing Firewall Logs
1.
Open a Web browser and enter
to access the 2Wire i3812V user interface; the
Home
page opens, displaying the aggregate upstream and downstream bandwidths.
2.
Click
Settings
; the
System Information
page opens.
Note:
The latest log appears at the bottom of the page; scroll down the page
to view your insertion mark.
Page 124 / 132
iNID -- i3812V User Guide
120
5.
Click
Clear Log
if you want to minimize the clutter from previous events when you are trying to diagnose
a problem.
6.
View the log.
−
Date and Time
: The date and time when the event occurs listing from the latest date on the top.
−
Severity: ERR
for errors,
INF
for information,
WRN
for warning, and so forth.
−
Details
: Includes the source and destination IP addresses as well as their ports, and a brief
description of the event.
Viewing Upgrade Logs
1.
Open a Web browser and enter
to access the 2Wire i3812V user interface; the
Home
page opens, displaying the aggregate upstream and downstream bandwidths.
2.
Click
Settings
; the
System Information
page opens.
Page 125 / 132
Finding Solutions
121
3.
Click
Logs
; the
Event Log
page opens.
4.
Click
Upgrade Log
, the
Upgrade Log
page opens, displaying the software versions information.