Page 26 / 32 Scroll up to view Page 21 - 25
5-
1
C
HAPTER
5
C
ONFIGURING
P
RINTER
S
ERVICES
The SpeedStream 2602
printer server supports Windows 95/98/NT/2000/ME and Unix platforms. To
configure print services for devices attached to the SpeedStream 2602:
1.
Install the Port Monitor program from the SpeedStream 2602 CD-ROM.
2.
Configure
the SpeedStream 2602 printer server for your operating system.
Install the Printer Port Monitor (Windows 95/98/NT)
1.
Insert the installation CD into your CD-ROM drive.
2.
In the PrintSvr directory, run the
setup.exe
program. The SpeedStream 2602 Port Monitor installation
program advises you to close all other Windows programs currently running on your computer.
3.
Close any other Windows applications; then click
Next
to continue.
4.
On the Select Components screen, click
Next
to
accept the defaults.
5.
On the Choose Destination Location screen, accept the default folder location or click
Browse
to
navigate to a new location; then click
Next
. The setup program will install the programs into the
specified folder.
6.
Select the program folder to contain the Uninstall Port Monitor program icon; then click
Next
.
7.
Enter the printer port name that will identify the port monitor in your system; then click
Next
.
8.
When the setup program finishes installing the port monitor, select
Yes, I want to restart my
computer now
; then click
OK
.
9.
Reboot your computer; then add the SpeedStream 2602 print server to your system as described in the
following section.
Configure the Print Server
After you install the Printer Port Monitor, locate the instructions below that are specific to your operating
system (Windows 95/98/NT, 2000, ME; Unix).
Windows 95/98/NT
If you are using Windows 95/98, first install the Printer Port Monitor as described in the previous section;
then add the SpeedStream 2602’s print server to your operating system.
1.
On the Windows 95/98 desktop, double-click
My Computer | Printers;
then double-click
Add Printer.
2.
In the Add Printer dialog box, click
Next
.
Page 27 / 32
5-
2
3.
Click to add a
Local printer
or
Network printer
.
4.
Specify the printer manufacturer and model.
5.
Select the monitored port; then click
Configure Port.
6.
Enter the IP address of the SpeedStream 2602 (
192.168.254.254
); then click
OK
.
7.
In the Add Printer Wizard dialog box, click
Next
to continue.
8.
Follow the prompts to complete the SpeedStream 2602 print server installation. The printer type you
specified will now be added to your
Printers
menu.
Windows 2000
1.
In Windows 2000, click
My Computer/Printers
; then
double-click
Add Printer
.
2.
Select
Network printer
; then click
Next
.
3.
Select
Connect to a printer on the Internet or on your intranet
and enter the IP address of the
SpeedStream 2602 in the URL field; then click
Next
.
4.
Specify the printer type attached to the SpeedStream 2602.
5.
Follow the prompts to complete the printer installation. The printer type you specified will now be
added to your
Printers
menu.
Windows ME
1.
In Windows ME, click
My Computers/Printers
;
then
double-click
Add Printer.
2.
Select
Network printer
;
then click
Next
.
3.
Enter the IP address of the SpeedStream 2602; then click
Next
.
4.
Specify the printer type attached to the SpeedStream 2602.
5.
Follow the prompts to complete the printer installation. The printer type you specified will now be
added to your
Printers
menu.
Unix Systems
Follow the traditional configuration procedure on Unix platforms to set up the SpeedStream 2602 print
server. The printer name is “lp.”
Page 28 / 32
A-
1
Appendix A
T
ROUBLESHOOTING
This section describes common problems you may encounter and their possible solutions. Use the panel
indicators to monitor and identify problems with the SpeedStream 2602. If you cannot resolve any
connection problems after checking the indicators,
refer to the following table.
Table A-1.
Troubleshooting Chart
Symptom
Action
LED Indicators
Power LED is Off
External power supply has failed or is
disconnected.
Check connections between the SpeedStream 2602, the external power supply, and
the wall outlet.
If the power indicator does not turn on when the power cord is plugged in, you may
have a problem with the power outlet, power cord, or external power supply.
If the unit powers off after running for a while, check for loose power connections,
power losses or surges at the power outlet.
If you still cannot isolate the problem, then the external power supply may be
defective. In this case, contact Siemens Technical Support for assistance.
Link LED is Off
Verify that the SpeedStream 2602 and attached devices are powered on.
Be sure the cable is plugged into both the SpeedStream 2602 and the corresponding
device.
Verify that the proper cable type is used and that its length does not exceed the
specified limits.
Be sure that the network interface on the attached device is configured for the proper
communication speed and duplex mode.
Check the adapter on the attached device and cable connections for possible defects.
Replace any defective adapter or cable if necessary.
Network Connection Problems
Cannot ping the
SpeedStream 2602
from the attached
LAN, or the
SpeedStream 2602
cannot ping any
device on the attached
LAN
Verify that the IP addresses are properly configured. For most applications, you
should use the SpeedStream 2602 DHCP function to dynamically assign IP addresses
to any host on the attached LAN. However, if you manually configure any IP
addresses on the LAN, verify that the same network address (network component of
the IP address) and subnet mask are used for both the SpeedStream 2602 and any
attached LAN devices.
Be sure the device you want to ping (or from which you are pinging) has been
configured for TCP/IP.
Management Problems
Cannot connect using
the Web browser
Be sure you configured the SpeedStream 2602
with a valid IP address, subnet mask
and default gateway.
Check that you have a valid network connection to the SpeedStream 2602 and that the
port you are using has not been disabled.
Check the network cabling between the management station and the SpeedStream
2602.
Forgot or lost the
password
Press the
Reset
button on the front panel (holding it down for at least five seconds) to
restore the factory defaults.
Page 29 / 32
A-
2
Technical Support
Before contacting Technical Support, please refer to the previous Troubleshooting table. If you are still
unable to resolve the problem, be prepared to provide the following information:
Model number (SpeedStream 2602)
Software version
Date of purchase or installation
Description of the problem
Technical Support for North America is available 24 hours a day, 7 days a week, by phone, email or online:
Phone:
877-823-6722
Email:
FTP:
ftp.speedstream.com
Page 30 / 32
B-
1
Appendix B
C
ABLES
Ethernet Cable
Cable Types and Specifications
Table B-1.
Cable Types and Specifications
Twisted-pair Cable
Caution:
DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with
RJ-45 connectors that conform with FCC standards.
For 10BASE-T/100BASE-TX connections, a twisted-pair cable must have two pairs of wires. Each wire
pair is identified by two different colors. An RJ-45 connector must be attached to both ends of the cable.
Except for the WAN port, all RJ-45 ports on the SpeedStream 2602 support automatic MDI/MDI-X
configuration, so you can use straight-through cable to attach the LAN ports to any network device.
However, when connecting the WAN port to a broadband modem, you will need to use either straight-
through or crossover cable, depending on the port type used on the modem.
The figure below illustrates how the pin numbering on the RJ-45 connector. Be sure to hold the connectors
in the same orientation when attaching the wires to the pins.
Figure B-1.
RJ-45 Pin Numbering
Cable
Type
Max. Length
Connector
10BASE-T
Cat. 3, 4, 5 100-ohm UTP
100 m (328 ft)
RJ-45
100BASE-TX
Cat. 5 100-ohm UTP
100 m (328 ft)
RJ-45

Rate

3.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top