This appendix covers the following topics:
Factory Settings
Technical Specifications
Page 117 / 122
Supplemental Information
117
R6100 WiFi Router
Factory Settings
You can return the router to its factory settings. Use the end of a paper clip or a similar object
to press and hold the
Reset
button on the back of the router for at least 7 seconds. The
router resets, and returns to the factory configuration settings shown in the following table.
Table 3.
Factory default settings
Feature
Default behavior
Router login
User login URL
www.routerlogin.com or www.routerlogin.net
User name (case-sensitive)
admin
Login password (case-sensitive)
password
Internet
connection
WAN MAC address
Use default hardware address
WAN MTU size
1500
Port speed
AutoSensing
Local network
(LAN)
LAN IP
192.168.1.1
Subnet mask
255.255.255.0
DHCP server
Enabled
DHCP range
192.168.1.2 to 192.168.1.254
Allow a registrar to configure this
router
Enabled
DHCP starting IP address
192.168.1.2
DHCP ending IP address
192.168.1.254
DMZ
Disabled
Time zone
GMT for WW except NA and GR, GMT+1 for GR, GMT-8
for NA
Time zone adjusted for daylight
savings time
Disabled
SNMP
Disabled
Firewall
Inbound (communications coming
in from the Internet)
Disabled (except traffic on port 80, the HTTP port)
Outbound (communications going
out to the Internet)
Enabled (all)
Source MAC filtering
Disabled
Page 118 / 122
Supplemental Information
118
R6100 WiFi Router
Wireless
Wireless communication
Enabled
SSID name
See router label
Security
WPA2-PSK (AES)
Broadcast SSID
Enabled
Transmission speed
Auto
*
Country/region
United States in the US; otherwise, varies by region
RF channel
6 until region selected
Operating mode
Up to 300 Mbps at 2.4 GHz, Up to 867 Mbps at 5 GHz
Firewall
Inbound (communications coming
in from the Internet)
Disabled (bars all unsolicited requests)
Outbound (communications going
out to the Internet)
Enabled (all)
*. Maximum wireless signal rate derived from IEEE Standard 802.11 specifications. Actual throughput can vary.
Network conditions and environmental factors, including volume of network traffic, building materials and
construction, and network overhead, lower actual data throughput rate.
Table 3.
Factory default settings
(continued)
Feature
Default behavior
Page 119 / 122
Supplemental Information
119
R6100 WiFi Router
Technical Specifications
Table 4.
R6100 Router specifications
Feature
Description
Data and routing protocols
TCP/IP, RIP-1, RIP-2, DHCP, PPPoE, PPTP, Bigpond, Dynamic DNS, UPnP,
and SMB
Power adapter
North America: 120V, 60 Hz, input
UK, Australia: 240V, 50 Hz, input
Europe: 230V, 50 Hz, input
All regions (output): 12 VDC @ 1.5A, output
Dimensions
Dimensions: 180 x 170 x 60 mm (7.08 x 6.69 x 2.36 in.)
Weight
Weight: 322 g (0.71 lbs)
Operating temperature
0° to 40°C
(32º to 104º F)
Operating humidity
90% maximum relative humidity, noncondensing
Electromagnetic emissions
FCC Part 15 Class B
VCCI Class B
EN 55 022 (CISPR 22), Class B C-Tick N10947
LAN
10BASE-T or 100BASE-Tx, RJ-45
WAN
10BASE-T or 100BASE-Tx, RJ-45
Wireless
Maximum wireless signal rate complies with the IEEE 802.11 standard. See the
footnote for the previous table.
Radio data rates
Auto Rate Sensing
Data encoding standards
IEEE 802.11ac 2.0
IEEE 802.11n version 2.0
IEEE 802.11n, IEEE 802.11g, IEEE 802.11b 2.4 GHz
IEEE 802.11n, IEEE 802.11a 5.0 GHz
Maximum number of
computers per wireless
network
Limited by the amount of wireless network traffic generated by each node
(typically 50–70 nodes).
Operating frequency range
2.4 GHz
2.412–2.462 GHz (US)
2.412–2.472 GHz (Japan)
2.412–2.472 GHz (Europe ETSI)
5 GHz
5.18–5.24 + 5.745–5.825 GHz (US)
5.18–5.24 GHz (Europe ETSI)
802.11 security
WPA-PSK, WPA2-PSK, and WPA/WPA2
Page 120 / 122
120
B
B.
Notification of Compliance
NETGEAR Dual Band - Wireless
Regulatory Compliance Information
This section includes user requirements for operating this product in accordance with National laws for usage of radio
spectrum and operation of radio devices. Failure of the end-user to comply with the applicable requirements may
result in unlawful operation and adverse action against the end-user by the applicable National regulatory authority.
This product's firmware limits operation to only the channels allowed in a particular Region or Country. Therefore, all
options described in this user's guide may not be available in your version of the product.
Europe – EU Declaration of Conformity
Products bearing the
marking comply with the following EU directives:
EMC Directive 2004/108/EC
Low Voltage Directive 2006/95/EC
If this product has telecommunications functionality, it also complies with the requirements of the following EU
Directive:
R&TTE Directive 1999/5/EC
Compliance with these directives implies conformity to harmonized European standards that are noted in the EU
Declaration of Conformity.
Intended for indoor use only in all EU member states, EFTA states, and Switzerland.
This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may
be limited to 10 mW EIRP in the frequency range of 2454 - 2483.5 MHz. For detailed information the end-user should
contact the national spectrum authority in France.
FCC Requirements for Operation in the United States
FCC Information to User
This product does not contain any user serviceable components and is to be used with approved antennas only.
Any product changes or modifications will invalidate all applicable regulatory certifications and approvals.
FCC Guidelines for Human Exposure
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
FCC Declaration of Conformity
We, NETGEAR, Inc., 350 East Plumeria Drive, San Jose, CA 95134, declare under our sole responsibility that the
R6100 WiFi Router complies with Part 15 Subpart B of FCC CFR47 Rules. Operation is subject to the following two
conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.

Rate

4 / 5 based on 1 vote.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top