5
Installation
8-Port 10/100/1000 Gigabit Switch with Webview
Chapter 3
Rack-Mount Placement
When rack-mounting the Switch, please observe the
following guidelines:
Elevated Operating Ambient
•
If installed in a closed
or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater
than room ambient. Therefore, consideration should
be given to installing the equipment in an environment
compatible with the maximum ambient temperature
(Tma) specified by the manufacturer.
Reduced Air Flow
•
Installation of the equipment
in a rack should be such that the amount of air flow
required for safe operation of the equipment is not
compromised.
Mechanical Loading
•
Mounting of the equipment in
the rack should be such that a hazardous condition is
not achieved due to uneven mechanical loading.
Circuit Overloading
•
Consideration should be given
to the connection of the equipment to the supply
circuit and the effect that overloading of the circuits
might have on overcurrent protection and supply
wiring.
Appropriate
consideration
of
equipment
nameplate ratings should be used when addressing
this concern.
Reliable Earthing
•
Reliable earthing of rack-mounted
equipment should be maintained. Particular attention
should be given to supply connections other than
direct connections to the branch circuit (e.g. use of
power strips).
To rack-mount the Switch in any standard 19-inch rack,
follow the instructions described below.
Place the Switch on a hard flat surface with the front
1.
panel facing you.
Attach a rack–mount bracket to one side of the Switch
2.
with the supplied screws. Then attach the other bracket
to the other side.
WARNING:
Make sure you use the screws
supplied with the mounting brackets. Using the
wrong screws could damage the Switch and
would invalidate your warranty.
Attaching the Brackets
Make sure the brackets are properly attached to the
3.
Switch.
Use the appropriate screws (not included) to securely
4.
attach the brackets to your rack.
Mounting in Rack