Page 31 / 98 Scroll up to view Page 26 - 30
31
HITRON CVE-30360 USER’S GUIDE
CABLE
FIGURE 6:
The Cable > System Info Screen
The following table describes the labels in this screen.
TABLE 7:
The Cable > System Info Screen
General Information
Vendor
Identification
This displays the name of the company that supplied the
CVE-30360.
Model Name
This displays the device’s model name (CVE-30360).
DOCSIS Mode
This displays the version of the Data Over Cable Service
Interface Specification (DOCSIS) standard to which the
CVE-30360 complies.
HW Version
This displays the version number of the CVE-30360’s
physical hardware.
SW Version
This displays the version number of the software that
controls the CVE-30360.
Boot ROM Version
This displays the version number of the program that
controls the CVE-30360’s boot procedure (in which the
main software is loaded).
MAC Address
RF MAC Address
This displays the Media Access Control (MAC) address of
the CVE-30360’s RF module. This is the module that
connects to the Internet through the
CATV
connection.
Ethernet MAC
Address
This displays the Media Access Control (MAC) address of
the CVE-30360’s Ethernet module. This is the module to
which you connect through the
LAN
ports.
WAN MAC Address
(in Routing Mode
This displays the Media Access Control (MAC) address of
the module that connects to the Internet through the
CATV
connection when the CVE-30360 is in routing mode.
Page 32 / 98
32
HITRON CVE-30360 USER’S GUIDE
CABLE
2.3
THE INITIALIZATION SCREEN
This screen displays the steps successfully taken to connect to the Internet over the
CATV
connection.
Use this screen for troubleshooting purposes to ensure that the CVE-30360 has
successfully connected to the Internet; if an error has occurred you can identify the
stage at which the failure occurred.
NOTE:
This screen displays when you first log in to the CVE-30360.
Click
Cable
>
Initialization
. The following screen displays.
Primary BSSID
MAC Address
This displays the Media Access Control (MAC) address of
the CVE-30360’s Basic Service Set IDentifier (BSSID).
This is the MAC address of the wireless module to which
wireless clients connect.
NOTE:
You may have additional BSSIDs, depending on
your contract with your service provider.
System Time
This displays the current date and time.
System Uptime
This displays the number of days, hours, minutes and
seconds since the CVE-30360 was last switched on or
rebooted.
Network Access
This field displays when you are connected to your service
provider, and shows whether or not your service provider
allows you to access the Internet over the
CATV
connection.
Permitted
displays if you can access the Internet.
Denied
displays if you cannot access the Internet.
TABLE 7:
The Cable > System Info Screen (continued)
Page 33 / 98
33
HITRON CVE-30360 USER’S GUIDE
CABLE
FIGURE 7:
The Cable > Initialization Screen
For each step:
Process
displays when the CVE-30360 is attempting to complete a connection
step.
Success
displays when the CVE-30360 has completed a connection step.
2.4
THE STATUS SCREEN
Use this screen to discover information about:
The nature of the upstream and downstream connection between the CVE-
30360 and the device to which it is connected through the
CATV
interface.
IP details of the CVE-30360’s WAN connection.
You can also configure the CVE-30360’s downstream center frequency.
Click
Cable
>
Status
. The following screen displays.
Page 34 / 98
34
HITRON CVE-30360 USER’S GUIDE
CABLE
FIGURE 8:
The Cable > Status Screen
The following table describes the labels in this screen.
TABLE 8:
The Cable > Status Screen
Network Access
This displays whether or not your service provider allows
you to access the Internet over the
CATV
connection.
Permitted
displays if you can access the Internet.
Denied
displays if you cannot access the Internet.
Downstream
NOTE:
The downstream signal is the signal transmitted to the CVE-30360.
Page 35 / 98
35
HITRON CVE-30360 USER’S GUIDE
CABLE
Frequency to Tune to
This displays the current center frequency in Hertz (Hz)
over which data is transmitted to the CVE-30360 over
the
CATV
interface. This is the frequency to which the
CVE-30360 is locked in; it will only scan for another
frequency if this frequency becomes unavailable.
If you want the CVE-30360 to attempt to connect at a
different frequency, enter it in the field and click
Apply
.
NOTE:
Do not change the frequency unless you have a
good reason to do so.
Scanning Start
Frequency
This displays the frequency in Hertz (Hz) at which the
CVE-30360 begins scanning for a connection over the
CATV
interface (if a frequency is not already locked in).
Channel Frequency
This displays the actual frequency of each downstream
data channel to which the CVE-30360 is connected.
Modulation
This displays the type of modulation that each
downstream channel uses. Possible modulation types
Signal Strength
This displays the power of the signal of each
downstream data channel to which the CVE-30360 is
connected, in dBmV (decibels above/below 1 millivolt).
Signal Noise Ratio
This displays the Signal to Noise Ratio (SNR) of each
downstream data channel to which the CVE-30360 is
connected, in dB (decibels).
Upstream
NOTE:
The upstream signal is the signal transmitted from the CVE-30360.
Channel ID
This displays the ID number of each channel on which
the upstream signal is transmitted.
Upstream Frequency
This displays the frequency in Herz (Hz) of each
upstream data channel to which the CVE-30360 is
connected.
Upstream Bandwidth
This displays the bandwidth of each upstream data
channel to which the CVE-30360 is connected (in Hertz).
SCDMA Mode
This displays the Synchronous Code Division Multiple
Access (SCDMA) mode of each channel on which the
upstream signal is transmitted.
Transmission Signal
Strength
This displays the transmitted power of the signal of each
upstream data channel to which the CVE-30360 is
connected, in dBmV (decibels above/below 1 millivolt).
Cable Modem IP Information
IP Address
This displays the CVE-30360’s WAN IP address. This IP
address is automatically assigned to the CVE-30360
Subnet Mask
This displays the CVE-30360’s WAN subnet mask.
TABLE 8:
The Cable > Status Screen (continued)

Rate