Page 11 / 28 Scroll up to view Page 6 - 10
11
Web Configuration
If you are incorporating the DWL-G810 into a network that contains all D-Link
devices, you do not need to use the Web Configuration utility. With its default
settings, the DWL-G810 will connect with other D-Link 802.11b or 802.11g devices
that are set to their default settings, with no configuration needed!
If your network contains devices other than D-Link devices, or if you wish to configure
the DWL-G810, you will need to do the following before using the Web Configuration
Utility:
Requirements for using the DWL-G810’s Web
Configuration Utility
You will need a JavaScript-enabled web-browser such as the Internet Ex-
plorer
6.0 or later, or the Netscape Navigator 6.0 or later.
The computer that you are using for initial configuration must have an IP
address within the same range as the IP address of the DWL-G810. The
DWL-G810 has a default IP address of
192.168.0.30
with a subnet mask of
255.255.255.0
You will need to assign a static IP address to the computer that you are
using to configure the DWL-G810, within the IP address range of the
DWL-G810. For example, you can assign a static IP address of 192.168.0.2
with a subnet mask of 255.255.255.0 to the computer you will use for
configuration. (Please refer to the Appendix section of the Quick Installation
Guide.)
Factory Default Settings for the DWL-G810
Operating Mode:
Infrastructure
SSID:
default
Channel:
6
Transmission rates:
Auto
Encryption:
Blank
(no password needed)
Administrator Password:
No
IP Address Mode:
Static
IP Address:
IP Subnet:
username:
admin
255.255.255.0
192.168.0.30
Page 12 / 28
12
Web Configuration (continued)
Whenever you want to configure your network or the DWL-G810, you can access the
Configuration Utility
by opening the Web browser and typing in the IP address of the
DWL-G810. The DWL-G810 default IP address is shown below:
Open the Web browser.
Type in the
IP address
of the access point.
(The IP address shown in this example is the
default setting. Use this IP address when
connecting to a network consisting of other
D-Link devices set to their default settings. If you
have changed the IP address of the DWL-G810
to conform to a network other than one with
D-Link devices, at their default setting, then input
that IP address in the Web browser, instead of
the default IP address shown.)
Type
admin
in the
User name
field.
Leave the
Password
blank.
Click
OK
.
The
Home
window will
appear. Please refer to
the
Quick Installation
Guide,
included with your
purchase, for more
information regarding the
Setup Wizard
,
accessible here. Once
you have completed the
configuration of the
DWL-G810, the current
settings will be displayed
in this window
Page 13 / 28
13
Operating Mode:
Select
Ad-Hoc
or
Infrastructure.
AP Name:
You may choose
to rename your DWL-G810,
especially if you have more
than one access point on your
network.
SSID:
The
Service Set
Identifier
is a unique name
that identifies a network. All
devices on a network must
share the same SSID name
in order to communicate. If
you choose to change the
SSID from the default
setting, input your new SSID
name in this field. The SSID
can be up to 32 characters in
length.
Network
Web Configuration (continued)
Wireless
This window displays the
default settings of the DWL-
G810. The default IP address
is 192.168.30. If you select
Dynamic IP Address
, you
will obtain a dynamic IP
address from a DHCP server
on your network.
The
Subnet
Mask
is
255.255.255.0. Input the IP
address of the
Gateway
(the
router on your network.)
Click
Apply
if you have
made any changes.
Page 14 / 28
14
Channel:
Devices communicating in Ad-Hoc mode must be set to the same channel.
WEP Encryption:
Select
Enable Encryption
to use
WEP
(
W
ired
E
quivalent
P
rivacy)
on the network. All devices on the network must share the same WEP selection – either
Enable
or
Disable
, and they must share the same WEP key. The WEP key is generated
from
ASCII
or
Hexadecimal
entries that are either 64-bit or 128-bit in length. When
enabling encryption, select the
Key Type
(ASCII or Hexadecimal) and then input the
appropriate digits or letters. Keys are case sensitive. You can create up to 4 keys.
Select the key you wish to use.
Tx Rate:
Select the transmission rate for the network.
Authentication:
Open System –
communicates the key across the network.
Shared Key –
devices must have identical WEP settings to communicate.
Click
Apply
if you have made any changes or additions.
Web Configuration (continued)
Wireless (continued)
Hexadecimal
digits consist of the numbers 0-9 and the letters A-F
ASCII
(American Standard Code for Information Interchange) is a code for
representing English letters as numbers from 0-127
Page 15 / 28
15
Web Configuration (continued)
Administrator Settings:
Change your password in this window. Re-enter the new
password to confirm. It can be up to 14 characters in length. Please keep a copy of your
password in a safe place.
Click
Apply
, if you have made any changes.
System Settings:
The current system settings can be saved as a file onto the local
hard drive by clicking
Save
. The saved file can be loaded back on the DWL-G810 by
clicking
Browse
.
When you have selected the settings file, click
Load
.
Click
Restore
to return to
Factory Default Settings
.
Firmware Upgrade:
Upgrade the firmware for the DWL-G810. Find upgrades to the
firmware at
.
After you have downloaded a firmware upgrade to
your local drive, click
Browse
. Select the firmware and click
Apply
to complete the
upgrade.
Admin

Rate

4 / 5 based on 1 vote.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top