Page 26 / 50 Scroll up to view Page 21 - 25
Ambit Broadband
Users Guide
26
4)
Cable Connector: This is where you connect the coaxial cable (not included) that leads
to the cable splitter (not included) or the cable wall outlet.
7. Web User Interface
Accessing the Web User Interface
This chapter describes how to access the wireless cable router via Web configuration interface. First,
please connect your PC to the cable router’s Ethernet port, via an Ethernet cable.
- Open the web browser and set the address to: http://192.168.100.1
for local access or
- Open the web browser and set the address to: http://Cable-RF-IP-address
for remote access or
- Open the web browser and set the address to: http://Public-gateway-IP-address:64680
for
remote access
1.
Click Login. Enter
user
for User name and
user
for Password, and then click
OK.
2. If the user enters an incorrect user name and/or password, the web user interface displays 401
Unauthorized.
*** User Name:
user
& Password:
user
only can access to MODEM, GATEWAY
Information Only
,
WIRELESS,
PARENTAL CONTROL, FIREWALL and TOOLS.
Page 27 / 50
Ambit Broadband
Users Guide
27
Web User Interface Home Page
A main menu is shown at the top of the pages and the user can select different options to view
wireless cable modem information. They include:
After login, user will see the CABLE MODEM page first. The layout is divided into 3 areas.
Menu Bar, Menu Tree and Configure Area. U10C020 is a wired router, which doesn
t support
WiFi access.
Menu Bar includes top level menu, like GATEWAY, WIRELESS and VPN. Once user select
the option in menu bar, Menu Tree will be changed correspondently.
To change parameter
settings, user needs to operate in Configure Area.
Below chapter is to go thro
ugh page by page, to ensure that you’re clear about each feature and
how to use it.
7.1 Cable Modem
User can select different options to view wireless cable modem’s information and real time status.
They include Information, Status, Downstream, Upstream, Upstream Burst, Operation Configuration,
Event Log options.
7.1.1 Information
This page is to show Cable Modem Information.
Page 28 / 50
Ambit Broadband
Users Guide
28
Label
Description
Cable Modem
Indicate the DOCSIS standard it’s compliant with.
MAC address
Unique hardware address of cable modem.
Serial Number
Unique manufacture ID number of a product.
Boot Code Version
Software version of device driver.
Software version
Software
Hardware Version
An internal ID number to identify hardware design.
CA Key
This is required by BPI. Cable modem will install a CA Key that
transferred from your service provider’s server after cable modem is
authenticated.
7.1.2 Status
This page is to show Cable Modem Status.
Label
Description
Item
List the item to be showed here.
Status
Status of the item.
Comments
Additional information for this item.
Page 29 / 50
Ambit Broadband
Users Guide
29
Acquire a Downstream
Channel
Current cable modem locking status. (Status field will show downstream
frequency. If comment field show
“Locked”, cable modem already locked this
frequency. Otherwise,
it will show “In Progress”, cable
modem is trying to lock this
frequency).
Connectivity State
After physical layer’s initialization, cable modem will be configured by a
DHCP server. Once succeeds to get an IP, that means cable modem is
online. In status column, it shows the progress. In comments Column, it
tells the reason why cable modem’s connectivity state is not ok.
Current
cable modem connectivity state. (Status field show “Ok”, cable modem is
operational. Otherwise,
it will show “In Progress”, cable
modem is in progress,
comments field will show current state).
Boot state
Current cable modem boot state. (Status field show “Ok”, cable modem is
operational. Otherwise, it will
show “In Progress”, cable modem is in progress,
comments field will show current state)
Security
Current cable modem security state. (Status field show “Disable”, Security is
disabled. Otherwise, it will
show “Enable”, Security is enabled, comments field will
show “BPI” or “BPI+”)
.
7.1.3 Downstream
This page is to Show Cable Modem Downstream.
Label
Description
Downstream lock
Display if the cable modem succeeded to lock to a downstream
channel.
Downstream Channel ID
Display the channel ID.
Downstream Frequency
Display the channel frequency cable modem is scanning.
Downstream Modulation
Display the modulation method that’s required for the downstream
channel locked by cable modem. This is decided by service
provider.
Page 30 / 50
Ambit Broadband
Users Guide
30
Downstream Symbol Rate
Display the symbol rate. Current cable modem downstream symbol
rate
(QAM64 is 5056941 sym/sec, QAM256 is 5360537 sym/sec).
Downstream Interleave
Depth
Current cable modem downstream Interleave depth
(8/16/32/64/128/other).
Downstream Receive Power
Level
Display the receiver power level after ranging process.
Downstream SNR
Display the SNR of this downstream channel.
7.1.4 Upstream
Label
Description
Upstream Lock
Current cable modem upstream lock status (Locked/Not
locked).
Upstream Channel ID
Current cable modem upstream channel identify.
Upstream Frequency
Current cable modem upstream frequency (Hz).
Upstream Modulation
Current cable modem upstream modulation type. (QPSK/
QAM8 /QAM16/ QAM32/ QAM64/ QAM128/ QAM256).
Upstream Symbol Rate
Current cable modem upstream symbol rate (Ksym/sec)
Upstream transmit Power Level
Current cable modem upstream transmit power (dBmV)
Upstream Mini-Slot Size
Current cable modem upstream mini-slot.

Rate

4.5 / 5 based on 2 votes.