NetVanta 2000 Series System Manual
Section 3, Network Turnup Procedure
61200361L1-1E
© 2002 ADTRAN, Inc.
29
4.
SUPPLYING POWER TO THE UNIT
NetVanta 2050 and 2100
The AC powered NetVanta 2050 and 2100 come equipped with a detachable 12 VDC at 800 mA
wallmount power supply for connecting to a grounded power receptacle. As shipped, the NetVanta 2050
and 2100 are set to factory default conditions. After installing the unit, the NetVanta 2050 and 2100 are
ready for power-up. To power-up the unit, connect the unit to an appropriate power source.
NetVanta 2300 and 2400
The AC powered NetVanta 2300 adn 2400 come equipped with an auto-sensing 100-240 VAC, 50-60 Hz
power supply for connecting to a grounded power receptacle. A grounded three plug detachable cable is
included with the shipment. As shipped, the NetVanta 2300 and 2400 are set to factory default conditions.
After installing the unit, the NetVanta 2300 and 2400 are ready for power-up. To power-up the unit,
connect the unit to an appropriate power source.
5.
INSTALLING NETVANTA 2000 SERIES MANAGEMENT COMPONENTS
Configuring the NetVanta 2000 series unit through the web interface requires a host computer with an
Ethernet interface and a web browser. ADTRAN recommends using Internet Explorer 5.0 or greater for
optimal viewing of configuration web pages.
The NetVanta 2000 series of products contains a default IP address of
10.10.10.1 and a netmask of
255.255.255.0. Select an IP address in the same range as the NetVanta unit and assign it to the host
computer running the web browser. An example IP address is
10.10.10.10 with a subnet mask of
255.255.255.0. This section contains detailed procedures for assigning the selected IP address to a host
computer for each of the popular operating systems.
•
This unit shall be installed in accordance with Article 400 and 364.8 of the NEC NFPA
70 when installed outside of a Restricted Access Location (i.e., central office, behind a
locked door, service personnel only area).
•
Power to the NetVanta 2050/2100 AC system must be from a grounded 90-130 VAC,
50/60 Hz source.
•
The power receptacle uses double-pole, neutral fusing.
•
Maximum recommended ambient operating temperature is 45
o
C.
•
This unit shall be installed in accordance with Article 400 and 364.8 of the NEC NFPA
70 when installed outside of a Restricted Access Location (i.e., central office, behind a
locked door, service personnel only area).
•
Power to the NetVanta 2300/2400 AC system must be from a grounded 100-240 VAC,
50/60 Hz source.
•
The power receptacle uses double-pole, neutral fusing.
•
Maximum recommended ambient operating temperature is 45
o
C.