Page 46 / 74 Scroll up to view Page 41 - 45
40
Wireless-G PrintServer
Chapter 7: Bi-Admin Management
The Bi-Admin Management Utility
Port
Physical Port
. Select the number of the Selected Physical Port from the drop-down menu. Select the
Handshake Signal,
Busy Only
or
Busy & Ack
. Select the Printer Type,
High Speed
or
Low Speed
.
Logical Port
. Select the Selected Logical Port from the drop-down menu and then the physical port you
want to map it to from the drop-down menu for
Map to Physical Port
. If you select Yes for Convert LF to
LF+CR, the LF (line feed) characters are changed to LF+CR (line feed + carriage return). In the field for
Prefix of Job
, enter the printer control string (in hexadecimal characters) to be sent to the printer before
each print job. This string cannot exceed 30 characters. In the field for
Suffix of Job
, enter the printer
control string (in hexadecimal characters) to be sent to the printer after each print job. This string cannot
exceed 30 characters.
Click the
Get Defaults
button if you want to cancel your changes and use the default settings.
When finished making your changes on this tab, click the
OK
button to save these changes, or click the
Cancel
button to undo your changes. For more information, click the
Help
button.
Figure 7-15: Configuration - Port
Downloaded from
www.Manualslib.com
manuals search engine
Page 47 / 74
41
Wireless-G PrintServer
Chapter 7: Bi-Admin Management
The Bi-Admin Management Utility
Wireless
SSID (Service Set Identifier)
. In the
SSID
field, enter the name of your wireless network. This is the
unique name shared by all devices in a wireless network. The SSID is case-sensitive and should have 32
characters or fewer.
Channel No
. If your network is set to ad-hoc mode, select your network’s channel setting from the
Channel No.
drop-down menu.
Network Type
. The Network Type setting shows a choice of two wireless modes. Select
Infrastructure
if
you want the PrintServer to communicate using an access point or wireless router. Select
Ad-Hoc
if you
want the PrintServer to communicate without using an access point or wireless router.
WEP Encryption
. If you want to enable WEP encryption for greater wireless security, click the
Enable
radio button. If you want to disable WEP encryption, keep the default,
Disable
. From the
WEP
Authentication
drop-down menu, select your wireless network’s authentication type. The default is set to
Open System
, for which the sender and the recipient do NOT use a WEP key for authentication. You can
also choose
Shared Key
, when the sender and recipient use a WEP key for authentication. This setting
should match the one on your network’s access point or wireless router.
In the
WEP Keys
section, select the level of WEP encryption,
64 bits
or
128-bits
. From the drop-down
menu, select the Default Key used by your wireless network. This indicates which WEP key your network
uses for WEP encryption. In the
Key1 (hex) to Key4 (hex)
fields, enter your network’s WEP keys. If you
are using 64-bit WEP encryption, then the key must consist of exactly 10 hexadecimal characters. If you
are using 128-bit WEP encryption, then the key must consist of exactly 26 hexadecimal characters. Valid
hexadecimal characters are “0”-“9” and “A”-“F”.
Click the
Link Info
button if you want to view information about the wireless connection.
Click the
Get Defaults
button if you want to cancel your changes and use the default settings.
When finished making your changes on this tab, click the
OK
button to save these changes, or click the
Cancel
button to undo your changes. For more information, click the
Help
button.
Figure 7-16: Configuration - Wireless
Downloaded from
www.Manualslib.com
manuals search engine
Page 48 / 74
42
Wireless-G PrintServer
Chapter 7: Bi-Admin Management
The Bi-Admin Management Utility
SNMP
SysContact
. Enter the name of the contact person in the
SysContact
field.
SysLocation
. Enter the location of the contact person in the
SysLocation
field.
Configuration Item
. From the
Configuration Item
box, select the number of the management station (M1-
M4) or trap receiver (T1-T4). The selected item’s information will be displayed below.
For management stations, you can change the station’s IP address, Community String, and Access
Permission level. In the
Manager IP Address
fields, enter the IP address of the management station with
the SNMP program installed. In the
Community String
field, enter the name of the SNMP community,
which is usually
public
or
private
. In the
Access Permission
section, select the desired level of access for
this management station,
Read Only
,
Read/Write
, or
Not Accessible
.
For trap receivers, you can change the trap receiver’s IP address, Community String, Trap Option, and
Trap Severity level. In the
Trap Receive IP Address
fields, enter the IP address of the trap receiver that will
be sent the trap messages or notifications. In the
Community String
field, enter the name of the SNMP
community, which is usually
public
or
private
. For the Trap Option setting, select
Enable
or
Disable
. For
the Trap Severity setting, select the desired level of severity, with 1 meaning least severe.
Click the
Get Defaults
button if you want to cancel your changes and use the default settings.
When finished making your changes on this tab, click the
OK
button to save these changes, or click the
Cancel
button to undo your changes. For more information, click the
Help
button.
Figure 7-17: Configuration - SNMP
Downloaded from
www.Manualslib.com
manuals search engine
Page 49 / 74
43
Wireless-G PrintServer
Chapter 7: Bi-Admin Management
The Bi-Admin Management Utility
Upgrade
. You may use this option to upgrade the firmware of the PrintServer. Follow these instructions:
1.
On the
Upgrade
screen, click the
Files
button.
2.
The
Detected LAN Cards
screen will appear. Select the LAN card the PrintServer is connected to, and then
click the
OK
button.
3.
Follow the on-screen instructions, and select the firmware file you want to use.
4.
View the
BIN File Information
screen, and click the
OK
button if you have selected the correct firmware
file. Click the
Cancel
button to select a different firmware file.
5.
On the
Upgrade
screen, click the
Upgrade
button. Click the
Cancel
button to cancel the firmware
upgrade. For more information, click the
Help
button.
Refresh
. This option allows you to refresh the device list after you change the name or IP address of a device.
The screen does not refresh automatically.
Exit
. This option allows you to exit the Bi-Admin program.
InitDevice
. The available options are Reset Device, Restore to Factory Default, Attached Remote, and Connected
Protocol.
If you click Attached Remote, the
Add Cross Segment Printer
screen appears. To add a cross segment print
server, enter its IP address in the fields provided, and click the
Set
button.
Click
Cancel
to undo any changes. For more information, click the
Help
button.
Diagnostic
. Diagnostic allows you to print a test page from either of the PrintServer’s ports.
Help
. The two options are Help Topics and About Bi-Admin. These help files offer extensive advice and details
about all of the PrintServer’s functions and capabilities.
Figure 7-19: Detected LAN Cards
Figure 7-20: BIN File Information
Figure 7-21: Add Cross Segment PrintServer
Figure 7-18: Upgrade
Downloaded from
www.Manualslib.com
manuals search engine
Page 50 / 74
44
Chapter 8: Internet Printing Protocol (IPP)
Overview
Wireless-G PrintServer
Chapter 8: Internet Printing Protocol (IPP)
Overview
Internet Printing Protocol (IPP) is a standards-based system that allows remote printing from a PC to any
accessible printer. Normally, the printer will be attached to a computer or other device that functions as an IPP
Server. For client PCs, it is necessary to install a compatible IPP Client program. The Client must also know the IP
Address or URL of the IPP Server.
The PrintServer contains the necessary firmware to act as an IPP Server. No additional configuration is
necessary. However, the following requirements must be met:
The PrintServer must have a valid IP Address. For printing via the Internet, the PrintServer’s IP Address must
be external (allocated by your ISP), rather than an IP Address on your local LAN.
Any Router, Gateway, or Firewall linking your LAN to the Internet must NOT block IPP. (IPP uses Port Services
631/TCP.)
You must advise clients of the correct URL or IP Address of the IPP Server. To use a URL rather than an IP
Address, you need to register the domain name for the URL.
Unless clients are using Windows 2000 or XP, you must provide your clients with the supplied IPP Client
software. If it is not convenient to provide the CD-ROM, supply the setup.exe file, located in the IPP folder.
Windows IPP Client Setup
Installing using setup.exe
1.
Run this program, located at d:\driver\ipp\setup.exe, to unzip the included files.
2.
The IPP Setup program will then run.
3.
Follow the prompts to complete the installation.
Downloaded from
www.Manualslib.com
manuals search engine

Rate

4 / 5 based on 1 vote.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top