Page 286 / 757 Scroll up to view Page 281 - 285
xStack
®
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
282
show multicast_fdb
Purpose
Used to display the contents of the switch’s multicast forwarding database.
Syntax
show multicast_fdb {[ vlan <vlan_name 32> | vlanid < vidlist > ]| mac_address
<macaddr>}
Description
The show multicast_fdb command displays the entries of the switch’s multicast forwarding
database.
Parameters
vlan_name
- The name of the VLAN on which the MAC address resides. The maximum
length is 32 characters.
vlanid
- Display the entries for the VLANs indicated by VID list.
macaddr
- Specifies a MAC address, for which FDB entries will be displayed.
If no parameter is specified, all multicast FDB entries will be displayed.
Restrictions
None.
Example usage:
To display the multicast MAC address table:
DGS-3627:admin# show multicast_fdb
Command: show multicast_fdb
VLAN Name
: default
MAC Address
: 01-00-00-00-00-01
Egress Ports
: 1:1-1:5,1:26,2:26
Mode
: Static
Total Entries : 1
show fdb
Purpose
Used to display the current unicast MAC address forwarding database.
Syntax
show fdb {port <port> | [ vlan <vlan_name 32> | vlanid <vidlist>] | mac_address
<macaddr> | static | aging_time}
Description
The show fdb command displays the current unicast MAC address forwarding database.
Parameters
port
- Displays the entries for one port.
vlan_name
- Displays the entries for a specific VLAN.
vlanid
- Display the entries for the VLANs indicated by VID list.
static
- Displays all permanent entries.
aging_time
- Displays the unicast MAC address aging time.
If no parameter is specified, system will display the unicast address table.
Restrictions
None.
Example usage:
To display the FDB table:
Page 287 / 757
xStack
®
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
283
DGS-3627:admin# show fdb
Command: show fdb
Unicast MAC Address Aging Time = 300
VID
VLAN Name
MAC Address
Port
Type
---- -------------------------------- ----------------- ------ -------
1
default
00-00-00-00-00-01 1:25
Dynamic
1
default
00-00-00-00-00-02 1:25
Dynamic
1
default
00-00-00-00-00-03 T1
Static
1
default
00-00-00-00-00-04 T1
Static
1
default
00-00-00-00-00-0A CPU
Self
1
default
00-00-00-00-00-06 -
Static
Total Entries: 6
DGS-3627:admin#
To display the security FDB table:
DGS-3627:admin# show fdb
Command: show fdb
Unicast MAC Address Aging Time = 300
VID
VLAN Name
MAC Address
Port
Type
----
----------------
-----------------
------
----------------
1
default
00-00-00-00-01-02
2:5
Permanent
1
default
00-01-02-03-04-00
CPU
Self
2
VLAN_2
00-00-01-02-03-04
-
Permanently Drop
1
default
00-00-00-00-00-07 1:3
Permanent
1
default
00-00-00-00-00-08 1:4
BlockByAddrBind
1
default
00-00-00-00-00-09 1:4
UnblockByAddrBind
1
default
00-00-00-00-00-10 1:5
BlockByMBA
1
default
00-00-00-00-00-11 1:5
UnBlockByMBA
1
default
00-00-00-00-00-12 1:6
BlockBySecurity
1
default
00-00-00-00-00-13 1:6
UnBlockBySecurity
1
default
00-00-00-00-00-14 1:7
JWAC_Authing
1
default
00-00-00-00-10-15 1:7
JWAC_Authed
1
default
00-00-00-00-10-16 1:7
JWAC_Blocked
1
default
00-00-00-00-10-18 1:8
Asymmetric_VLAN
1
default
00-00-00-00-10-19
-
BlackHole
1
default
00-00-00-00-10-21 1:11
Del_on_Reset
1
default
00-00-00-00-10-22 1:12
Del_on_Timeout
1
default
00-00-00-00-10-23 1:13
Secured_Permanent
1
default
00-00-00-00-10-24 1:14
Del_on_Reset
1
default
00-00-00-00-10-25 1:15
SVL
Total Entries: 19
DGS-3627:admin#
show multicast filtering_mode
Purpose
Used to show the multicast packet filtering mode for VLANs.
Syntax
show multicast filtering_mode {vlan <vlan_name 32>}
Description
The show multicast vlan_filtering_mode command show the multicast packet filtering mode
for VLAN.
Page 288 / 757
xStack
®
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
284
show multicast filtering_mode
Parameters
vlanid
- Specifies a list of VLANs to be configured.
vlan
– Specifies the VLAN name to be configured.
If no parameter is specified, the device will show all multicast filtering settings in the device.
Restrictions
None.
Example usage:
To show the multicast vlan_filtering_mode for VLANs:
DGS-3627:admin# show multicast filtering_mode
Command: show multicast filtering_mode
VLAN Name
Multicast Filter Mode
------------------- ---------------------------
Sales
forward_all_groups
PM
forward_all_groups
Customer
filter_unregistered_groups
DGS-3627:admin#
Page 289 / 757
xStack
®
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
285
37
FLASH FILE SYSTEM (FFS) COMMANDS
The Flash File System (FFS) commands in the Command Line Interface (CLI) are listed (along with the appropriate
parameters) in the following table.
Command
Parameters
show storage_media_info
{[unit <unitid 1-12> | all]}
cd
{<pathname 64>}
dir
{{unit [<unitid 1-12>|all]} <drive_id>}
rename
{{unit <unit_id 1-12>} <drive_id>} <pathname 64> <filename 64>
erase
{{unit <unit_id 1-12>} <drive_id>} <pathname 64>
copy
{<drive_id>} <pathname 64> {{unit <unit_id 1-12>} <drive_id>} <pathname 64>
Each command is listed, in detail, in the following sections.
show storage_media_info
Purpose
This command is used to display the information of the storage media available on the
system.
Syntax
show storage_media_info {[unit <unitid 1-12> | all]}
Description
This command is used to display the information of the storage media available on the
system. There can be one or multiple media on the system. The information for a media
includes the drive number, the media identification.
Parameters
unit
- (Optional) Specifies a unit ID if in the stacking system. If not specified, it refers to the
master unit.
<unitid 1-12>
- Enter the unit ID here. This value must be between 1 and 12.
all
- Specifies all units.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
To display the storage media’s information:
DGS-3627:admin#show storage_media_info
Command: show storage_media_info
------------------------------------------------------
Unit ID is 1
Drive
Media_Type
Size
Label
FS_Type
C:
Flash
15 MB
FLASH-A
FAT16_V2
------------------------------------------------------
DGS-3627:admin#
Page 290 / 757
xStack
®
DGS-3600 Series Layer 3 Gigabit Ethernet Managed Switch CLI Manual
286
cd
Purpose
This command is used to change the current directory.
Syntax
cd {<pathname 64>}
Description
This command is used to change the current directory. The current directory is changed
under the current drive. If you want to change the working directory to the directory in another
drive, then you need to change the current drive to the desired drive, and then change the
current directory.
The current drive and current directory will be displayed if the <pathname>
is not specified.
Parameters
<pathname 64>
- (Optional) Specifies the directory to be removed. The path name can be
specified either as a full path name or partial name. For partial path name, it indicates the file
is in the current directory. This name can be up to 64 characters long.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
To change to other directory or display current directory path:
DGS-3627:admin#cd c:\
Command: cd c:\
Change Unit 1 path to c:\
Success.
DGS-3627:admin#
dir
Purpose
List all of the files located in a directory of a drive.
Syntax
dir {{unit [<unitid 1-12>|all]} <drive_id>}
Description
List all of the files located in a directory of a drive.
If pathname is not specified, then all of the files in the specified drive will be displayed. If
none of the parameters are specified, the files in the current drive will be displayed.
Parameters
unit
- (Optional) Specifies a unit ID if in the stacking system. If not specified, it refers to the
master unit.
<unit 1-12>
- Enter the unit ID here. This value must be between 1 and 12.
all
- (Optional) Lists all unit located files in stacking system.
<drive_id>
- Specifies the drive ID used.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example usage:
List the files without specified the parameter “all”:

Rate

4.5 / 5 based on 2 votes.

Bookmark Our Site

Press Ctrl + D to add this site to your favorites!

Share
Top