Page 86 / 998
Scroll up to view Page 81 - 85
Software update
Emergency command reference
iMG/RG Software Reference Manual (System Configuration)
1-54
See also
EMERGENCY SET IPINTERFACE GATEWAY
EMERGENCY SHOW
EMERGENCY UPDATE
1.3.4.1.7 EMERGENCY SHOW
Syntax
EMERGENCY SHOW
Description
This command displays the current emergency configuration settings. These settings are not active
until the EMERGENCY UPDATE command is entered or the Residential Gateway configuration is
saved and then the system is restarted.
Example
emergency show
EMERGENCY CONFIGURATION
- GENERAL PARAMETERS
device ip address: 192.168.1.1
device netmask: 255.255.255.0
gateway ip address: 192.168.1.254
vlan tag id: 2
vlan tagged port: LAN4
Syntax
EMERGENCY UPDATE
1.3.4.1.8 EMERGENCY UPDATE
Syntax
EMERGENCY UPDATE
Description
This command update the Residential Gateway e2prom with the new emergency config-
uration data. To display the current emergency configuration settings use the EMER-
GENCY SHOW command.
Example
emergency update
See also
EMERGENCY SHOW
1.4
Software update
Gateway software consists of the Main Application code plus additional support files and the Recovery Applica-
tion code. All these files are stored permanently into the
flash
memory under the main partition or recovery
partition depending on the file type.
To upgrade software or simply load into the gateway a specific file, it's possible use one of the following solu-
tions depending on the type of upgrade requested:
•
Web Interface, when available is designed to update the Main Application code or the Recovery Application
code. Web interface is available only on the main code (not on recovery)
Page 87 / 998
Emergency command reference
Software update
1-55
iMG/RG Software Reference Manual (System Configuration)
•
SwUpdate module, available both on Main Application code and Recovery Application Code designed to
update the Main Application code or the Recovery Application code and to upload any
configuration file
Product Name
Loader
SwUpdate
Web Interface
AT-RG613
Loader_RG600E_x-y_z.exe
rg600E-x-y_z.zip
N/A
AT-iMG616
Loader_IMG616E_x-y_z.exe
iMG616E-x-y_z.zip
N/A
AT-iMG634A
AT-iMG634WA
N/A
iMG634A-x-y_z.zip
iMG634A-main-x-y_z.bin
AT-iMG634B
AT-iMG634WB
N/A
iMG634B-x-y_z.zip
iMG634B-main-x-y_z.bin
AT-iMG624A
N/A
iMG624A-x-y_z.zip
iMG624A-main-x-y_z.bin
AT-iMG624B
N/A
iMG624B-x-y_z.zip
iMG624B-main-x-y_z.bin
AT-iMG634A-R2
AT-iMG634WA-R2
N/A
iMG634A-R2-x-y_z.zip
iMG634A-R2-main-x-y_z.bin
AT-iMG634B-R2
AT-iMG634WB-R2
N/A
iMG634B-R2-x-y_z.zip
iMG634B-R2-main-x-y_z.bin
AT-iMG624A-R2
N/A
iMG624A-R2-x-y_z.zip
iMG624A-R2-main-x-y_z.bin
AT-iMG626MOD
N/A
iMG626-x-y_z.zip
iMG626-main-x-y-z.bin
AT-iMG646MOD
N/A
iMG646-x-y_z.zip
iMG646-main-x-y-z.bin
AT-iMG726MOD
N/A
iMG726-x-y_z.zip
iMG726-main-x-y-z.bin
AT-iMG746MOD
N/A
iMG746-x-y_z.zip
iMG746-main-x-y-z.bin
AT-iBG915FX
N/A
iBG915FX-x-y_z.zip
iBG915FX-main-x-y-z.bin
Page 88 / 998
Software update
Emergency command reference
iMG/RG Software Reference Manual (System Configuration)
1-56
•
Recovery Application Software Naming Convention table
Product Name
Loader
SwUpdate
Web Interface
AT-RG613
RecLoader_RG600_a-
b_c.exe
rg6xx-rec-a-b_c.zip
N/A
AT-iMG616
RecLoader_IMG616E_a-
b_c.exe
iMG616E-rec-a-b_c.zip
N/A
AT-iMG634A
AT-iMG634WA
N/A
iMG634A-rec-a-b_c.zip
iMG634A-recovery-a-b_c.bin
AT-iMG634B
AT-iMG634WB
N/A
iMG634B-rec-a-b_c.zip
iMG634B-recovery-a-b_c.bin
AT-iMG624A
N/A
iMG624A-rec-a-b_c.zip
iMG624A-recovery-a-b_c.bin
AT-iMG624B
N/A
iMG624B-rec-a-b_c.zip
iMG624B-recovery-a-b_c.bin
AT-iMG634A-R2
AT-iMG634WA-R2
N/A
iMG634A-R2-rec-a-
b_c.zip
iMG634A-R2-recovery-a-
b_c.bin
AT-iMG634B-R2
AT-iMG634WB-R2
N/A
iMG634B-R2-rec-a-
b_c.zip
iMG634B-R2-recovery-a-
b_c.bin
AT-iMG624A-R2
N/A
iMG624A-R2-rec-a-
b_c.zip
iMG624A-R2-recovery-a-
b_c.bin
AT-iMG626MOD
N/A
iMG626-rec-a-b_c.zip
iMG626-recovery-a-b_c.bin
AT-iMG646MOD
N/A
iMG646-rec-a-b_c.zip
iMG646-recovery-a-b_c.bin
AT-iMG726MOD
N/A
iMG726-rec-a-b_c.zip
iMG726-recovery-a-b_c.bin
AT-iMG746MOD
N/A
iMG746-rec-a-b_c.zip
iMG746-recovery-a-b_c.bin
AT-iBG915FX
N/A
iBG915FX-rec-a-b_c.zip
iBG915FX-recovery-a-b_c.bin
Page 89 / 998
Windows™ Loader
Software update
1-57
iMG/RG Software Reference Manual (System Configuration)
•
FLASH image Naming Convention table
1.4.1
Windows™ Loader
To upgrade the AT-RG600 Residential Gateway, a special Windows™ based application has been developed, the
Loader.
Product Name
Flash Image
AT-RG613
rg600E-image-2-2_y-3-7_x.bin
AT-iMG616
iMG616E-image-2-2_y-3-7_x.bin
AT-iMG634A
AT-iMG634WA
iMG634A-image-3-7_x.bin
AT-iMG634B
AT-iMG634WB
iMG634B-image-3-7_x.bin
AT-iMG624A
iMG624A-image-3-7_x.bin
AT-iMG624B
iMG624B-image-3-7_x.bin
AT-iMG634A-R2
AT-iMG634WA-R2
iMG634A-R2-image-3-7_x.bin
AT-iMG634B-R2
AT-iMG634WB-R2
iMG634B-R2-image-3-7_x.bin
AT-iMG624A-R2
iMG624A-R2-image-3-7_x.bin
AT-iMG626MOD
iMG626-image-3-7_x.bin
AT-iMG646MOD
iMG646-image-3-7_x.bin
AT-iMG726MOD
iMG726-image-3-7_x.bin
AT-iMG746MOD
iMG726-image-3-7_x.bin
AT-iBG915FX
iBG915FX-image-3-7_x.bin
Page 90 / 998
Software update
Upgrade via Web Interface
iMG/RG Software Reference Manual (System Configuration)
1-58
The loader uses the TFTP services provided by the gateway to download on the unit the application file plus all
other support files avoiding the user to download each file separately.
The loader can be used to upgrade an existing software version or can be used to download a new complete
software release if the gateway is running in recovery mode.
When the Loader is used to upgrade the gateway from a previous software release, all the existing configura-
tion files are kept.
Note:
Starting with release 3-1-0, a special Loader application has been developed to also upgrade the
recovery application code installed in the recovery partition. The graphical interface is the same as that
used for the main application code.
When using the Loader, the IP address of the residential Gateway must be selected and the SNMPv2 commu-
nity write name is requested as session password.
FIGURE 1-4
The Windows™ Loader
1.4.2
Upgrade via Web Interface
Some gateways provide a web interface to load the Main Application code or the Recovery Application code.
Figure 1-4
shows the Web Interface main page. To load a software, click the Firmware Update menu.
On the Firmware Update page (See
Figure 1-6
) push the “Browse” button, select the software file to be
uploaded and click OK:
•
iMG634xxx-main-x-y_z.bin to load the Main Application code.